Comparison of clinical assessment and multifrequency bioimpedance analysis as methods of estimating volume status in peritoneal dialysis patients - A single-center experience (CROSBI ID 262627)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vujičić, Božidar ; Dorčić, Gordan ; Babić, Vesna ; Rundić, Anamarija ; Devčić, Bosiljka ; Šimac, Davor Viktor ; Zaputović, Luka ; Rački, Sanjin Comparison of clinical assessment and multifrequency bioimpedance analysis as methods of estimating volume status in peritoneal dialysis patients - A single-center experience // Clinical nephrology, 91 (2019), 334-343. doi: 10.5414/CN109158

Podaci o odgovornosti

Vujičić, Božidar ; Dorčić, Gordan ; Babić, Vesna ; Rundić, Anamarija ; Devčić, Bosiljka ; Šimac, Davor Viktor ; Zaputović, Luka ; Rački, Sanjin

engleski

Comparison of clinical assessment and multifrequency bioimpedance analysis as methods of estimating volume status in peritoneal dialysis patients - A single-center experience

INTRODUCTION. Clinical assessment (CA) is frequently used for the evaluation of volume status in peritoneal dialysis (PD) patients despite its subjectivity. Multiple-frequency bioelectrical impedance analysis (MF-BIA) is objective, accurate, and quick, proving to be a promising technique for measuring volume status. The aim of this study was to assess volume status in PD patients using CA and MF- BIA and to compare results. MATERIALS AND METHODS. Incident PD patients were prospectively analyzed between January 1, 2014, and January 1, 2016, at the Clinical Hospital Center of -Rijeka, Croatia. Volume status measurements were performed once a month for 6 consecutive months. The presence of symptoms and signs associated with hyper- or hypovolemia were detected by CA. Euvolemia was defined as a symptom-free state or up to 2 symptoms maximum. Patients lacking up to 1.2 L of volume or with up to 1.2 L in excess were considered euvolemic, as measured by MF-BIA. RESULTS. A total of 45 PD patients were analyzed ; 51% were men, 27% were diabetic, the mean age was 52±26 years, and PD duration was 11.5±6.5 months. In comparison to MF-BIA, CA showed a significant difference in detected hypervolemia between baseline and follow-up (p=0.708 vs. p=0.01, respectively) and among all measurements (p<0.01). Contrary to CA, volume status measured by MF-BIA correlated significantly with systolic and diastolic blood pressure (R=0.29 ; p≤0.01 and R=0.26 ; p≤0.01, respectively). CA showed low sensitivity (0.24) and high specificity (0.92) in detecting hypervolemia. CONCLUSION. MF-BIA is an effective, objective, and safe method for assessing volume status in PD patients. Longitudinal monitoring of body composition changes - including hydration state - leading to adequate therapeutic intervention is a promising and potential application of MF- BIA along with CA.

Multiple-frequency bioelectrical impedance analysis ; volume status ; assessment ; hypervolemia ; peritoneal dialysis