Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes (CROSBI ID 260449)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Lippi, Giuseppe ; Salvagno, Gian Luca ; Lampus, Simona ; Danese, Elisa ; Gelati, Matteo ; Bovo, Chiara ; Montagnana, Martina ; Šimundić, Ana-Maria Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes // Clinical chemistry and laboratory medicine, 56 (2018), 12; 2125-2131. doi: 10.1515/cclm-2018-0523

Podaci o odgovornosti

Lippi, Giuseppe ; Salvagno, Gian Luca ; Lampus, Simona ; Danese, Elisa ; Gelati, Matteo ; Bovo, Chiara ; Montagnana, Martina ; Šimundić, Ana-Maria

engleski

Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes

Although it is known that glucose concentration exhibits a time-dependent decay in uncentrifuged serum and lithium-heparin blood tubes, no evidence exists on how this variation may depend on blood cell counts (CBC) and volumes. Venous blood was drawn from 30 non fasting healthy volunteers into three serum and three lithium-heparin tubes. One serum and lithium-heparin tubes were centrifuged within 15 min after collection and glucose was measured with a hexokinase assay. The second and third serum and lithium-heparin tubes were maintained at room temperature for 1 and 2 h after the first tubes were centrifuged. These other tubes were then centrifuged and glucose was measured. CBC was performed in the first lithium-heparin tube, before centrifugation. RESULTS: The mean decrease of glucose was higher in lithium-heparin plasma than in serum (0.33 vs. 0.24 mmol/L/h ; p<0.001). Glucose concentration decreased by 7% and 5% per hour in lithium-heparin plasma and serum, respectively. In univariate analysis, the absolute decrease of glucose concentration was associated with sex (higher in men than in women), red blood cell (RBC) count, hematocrit, white blood cell (WBC) count, neutrophils and monocytes in both lithium-heparin plasma and serum. In multivariate analysis, the decrease of glucose concentration remained independently associated with RBC, WBC, neutrophils and monocytes in both sample matrices. No significant association was found with platelet number and erythrocyte or platelet volume. CONCLUSIONS: Glucose concentration decrease in uncentrifuged lithium-heparin and serum tubes depends on the baseline number of RBC, WBC, neutrophils and monocytes within the tubes.

blood tubes ; diabetes ; errors ; glucose ; preanalytical variability

Rad/časopis indeksiran je i u bazama: Pathway Studio ; Primo Central (ExLibris) ; ProQuest ; Rad/časopis je indeksiran i u Bazama: Pathway Studio ; Primo Central ; ProQuestPublons ; PubsHub ; QOAM ; ReadCube ; Reaxys ; SCImago (SJR) ; Sherpa/RoMEO ; Summon ; TDNet ; TEMA ; Text Mining ; ulrichsweb ; WanFang Data ; WorldCat.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

56 (12)

2018.

2125-2131

objavljeno

1434-6621

1437-4331

10.1515/cclm-2018-0523

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost