Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Performance analysis of a CPV/T-DC integrated system adopted for the energy requirements of a supermarket (CROSBI ID 259962)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Renno, Carlo ; D'Agostino, Diana ; Minichiello, Francesco ; Petito, Fabio ; Balen, Igor Performance analysis of a CPV/T-DC integrated system adopted for the energy requirements of a supermarket // Applied thermal engineering, 149 (2019), 25; 231-248. doi: 10.1016/j.applthermaleng.2018.12.007

Podaci o odgovornosti

Renno, Carlo ; D'Agostino, Diana ; Minichiello, Francesco ; Petito, Fabio ; Balen, Igor

engleski

Performance analysis of a CPV/T-DC integrated system adopted for the energy requirements of a supermarket

In this paper, a model that analyses the coupling of a concentrating photovoltaic and thermal (CPV/T) system with a desiccant cooling (DC) system used to satisfy the energy loads required by a supermarket, is presented. A detailed analysis of the supermarket electrical and thermal loads is conducted in different periods of the year: summer, winter and half seasons. A CPV/T system linear focus configuration is considered, and its sizing as a function of the solar Direct Normal Irradiance (DNI) is realized for each period of the year. Hence, an Artificial Neural Network (ANN) is used to model carefully the DNI adopting experimental data in the simulation process. The coupling between the CPV/T and DC systems allows to obtain energy and economic savings during the year compared with a conventional solution, considering accurately in the modelling: supermarket energy loads, solar radiation, environmental conditions, etc. In particular, the analysis of three case studies is performed, where the main aim has been to size the CPV/T-DC integrated system and to study how it can match the different supermarket energy needs. The three solutions are analyzed from an energetic and economic point of view in order to demonstrate the effectiveness of the solution proposed.

Concentrating photovoltaic and thermal system ; Desiccant cooling system ; Supermarket ; Electrical and thermal loads ; DNI model

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

149 (25)

2019.

231-248

objavljeno

1359-4311

10.1016/j.applthermaleng.2018.12.007

Povezanost rada

Elektrotehnika, Strojarstvo

Poveznice
Indeksiranost