Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Analysis of Tight Fit Clothing 3D Construction Based on Parametric and Scanned Body Models (CROSBI ID 672181)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Mahnic Naglic, Maja ; Petrak, Slavenka ; Stjepanovic Zoran Analysis of Tight Fit Clothing 3D Construction Based on Parametric and Scanned Body Models // Book of Abstracts 7th International Conference on 3D Body Scanning Technologies / D'Apuzzo, Nicola (ur.). Lugano: Hometrica Consulting, Switzerland, 2016. str. 20-20

Podaci o odgovornosti

Mahnic Naglic, Maja ; Petrak, Slavenka ; Stjepanovic Zoran

engleski

Analysis of Tight Fit Clothing 3D Construction Based on Parametric and Scanned Body Models

The contribution presents the study related to the use of parametric and 3D scanned computer body models for designing and constructing the skin-tight garments. A number of methods and systems have already been developed that allow an efficient 3D design of garment patterns in a virtual environment using the computerbased body models. Such systems usually offer solutions for creating the models of garments to be manufactured from elastic materials, which come close to the body. Here, the designer designs the garment and also constructs a 3D model of the garment on the surface of the virtual model of the body. After finishing the computer design of the surfaces that simulate 3D patterns, the transformation of three-dimensional to two-dimensional patterns is performed. As a prototype of the garment, on which the study was conducted, the model of a wet diving suit was chosen. Using the 3D simulation method on the parametric and scanned body model, we have analysed the fit of designed prototypes in static and dynamic body postures.

3D body scanning, CAD system, parametric body model, tight fit clothing, diving suit

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

20-20.

2016.

objavljeno

Podaci o matičnoj publikaciji

Book of Abstracts 7th International Conference on 3D Body Scanning Technologies

D'Apuzzo, Nicola

Lugano: Hometrica Consulting, Switzerland

Podaci o skupu

7th International Conference on 3D Body Scanning Technologies

predavanje

30.11.2016-01.12.2016

Lugano, Švicarska

Povezanost rada

Trošak objave rada u otvorenom pristupu

Tekstilna tehnologija