Investigation of the change in nickel content in ideal and real carbon systems at temperatures up to 2400°C (CROSBI ID 259256)

Prilog u časopisu | izvorni znanstveni rad

Rađenović, Ankica ; Ugarković, Dubravka ; Legin- Kolar, Mira Investigation of the change in nickel content in ideal and real carbon systems at temperatures up to 2400°C // Nafta : exploration, production, processing, petrochemistry, 43 (1992), 6; 305-311

Podaci o odgovornosti

Rađenović, Ankica ; Ugarković, Dubravka ; Legin- Kolar, Mira

engleski

Investigation of the change in nickel content in ideal and real carbon systems at temperatures up to 2400°C

The change of nickel content in samples of petroleum coke with and without compounds of nickel (NiO, NiS, NiS1.03, NiSO4) as real systems related to ideal systems (graphite- NiO, graphite- NiS, graphite- NiS1.03, graphite- NiSO4) depending on high temperature treatment (HTT) and hiting time have been investigated. The results of investigations showed that better separation occurs when nickel is present as oxides than as sulphides. These investigations suggest that the change of nickel content, except on temperature and heating time, depends also on the sorts of it chemical compounds present in samples.

petroleum coke, nickel, high temperature treatment (HTT)

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

43 (6)

1992.

305-311

objavljeno

0027-755X

1849-1189

Povezanost rada

Kemija, Metalurgija