Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power (CROSBI ID 259141)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Nikolovski, Srete ; Hamid, Reza, Baghaee ; Dragan Mlakić Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power // IEEE Systems Journal, 13 (2019), 1; 1-11. doi: 10.1109/JSYST.2018.2889981

Podaci o odgovornosti

Nikolovski, Srete ; Hamid, Reza, Baghaee ; Dragan Mlakić

engleski

Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power

The question of the islanding operation of distributed generations (DGs) and that of the current inadmissible networking policy of islanding operations sets a demanding task for an efficient islanding detection, preferably from a single place, using either passive or active islanding-detection method. Islanding detection shall be faster than the fast automatic reclosing of the connected transmission line connected to the DG unit. This paper deals with the detection method of islanded operation mode for the large power synchronous generator-based DGs in bio-mass power plants. The proposed method has been applied to a practical 10-MW bio-mass power plant and experimentally tested to verify the simulation results. The rate of change of reactive power (dQ/dt >) criterion is derived as a yardstick for islanding detection. The practical power plant model has been implemented to be simulated in DIgSILENT PowerFactory and MATLAB/Simulink software environments. Offline digital time-domain simulations and experimental tests on a practical bio-mass power plant reveals that the proposed method efficiently, and authentically detects islanding phenomena with high accuracy, low detection time, very small number of non-detected zones and, with almost zero power balance (ΔP = 0).

Automatic voltage regulator ; bio-mass power plant ; islanding detection ; reactive power ; synchronous generator

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

13 (1)

2019.

1-11

objavljeno

1932-8184

1937-9234

10.1109/JSYST.2018.2889981

Trošak objave rada u otvorenom pristupu

Povezanost rada

Elektrotehnika

Poveznice
Indeksiranost