Establishment of diagnostic reference levels for typical radiography examinations in the west region of Croatia (CROSBI ID 258567)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šegota, Doris ; Diklić, Ana ; Jurković, Slaven Establishment of diagnostic reference levels for typical radiography examinations in the west region of Croatia // Nuclear technology & radiation protection, 34 (2019), 01; 102-106. doi: 10.2298/NTRP180831015S

Podaci o odgovornosti

Šegota, Doris ; Diklić, Ana ; Jurković, Slaven

engleski

Establishment of diagnostic reference levels for typical radiography examinations in the west region of Croatia

Majority of health institutions in Croatia do not have medical physicists in diagnostic radiology. Regarding this, in the west region of Croatia collaboration between public health institution and University Hospital Rijeka was initiated in 2015. Quality Assurance programme was implemented in these public health institutions during 2015 and 2016 and the next step was to assess patient doses for the most frequent X-ray examinations. It included five public health institutions: 1 university hospital, 1 general hospital, 1 special hospital, 2 public health institutions with 13 facilities. The aim of this study was to carry out assessment of patient doses and to establish local diagnostic reference levels for entrance surface air kerma for every institution for six most frequent X- ray examinations. Also, local diagnostic reference levels for the whole west region of Croatia were established and compared with the national diagnostic reference levels and latest published data. Median entrance surface air kerma values for thorax PA, thorax LAT, cervical spine AP, thoracic spine AP, lumbar spine AP, pelvis AP and sinuses are 0.14 mGy, 0.50 mGy, 0.52 mGy, 1.50 mGy, 2.52 mGy, 2.03 mGy and 1.03 mGy, respectively. Diagnostic reference levels proposed for our region were comparable with other studies.

DRL, radiography, X-ray

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

34 (01)

2019.

102-106

objavljeno

1451-3994

10.2298/NTRP180831015S