Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Concept of sample-specific correction of immunoassay results for precise and accurate IgG quantification in horse plasma (CROSBI ID 256766)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Halassy, Beata ; Kurtović, Tihana ; Lang Balija, Maja ; Brgles, Marija ; Tunjić, Monika ; Sviben, Dora Concept of sample-specific correction of immunoassay results for precise and accurate IgG quantification in horse plasma // Journal of pharmaceutical and biomedical analysis, 164 (2019), 276-282. doi: 10.1016/j.jpba.2018.10.020

Podaci o odgovornosti

Halassy, Beata ; Kurtović, Tihana ; Lang Balija, Maja ; Brgles, Marija ; Tunjić, Monika ; Sviben, Dora

engleski

Concept of sample-specific correction of immunoassay results for precise and accurate IgG quantification in horse plasma

The hyperimmune horse plasma (HHP), prepared through active immunisation of horses with an antigen of interest, is the most common starting material for antitoxin (animal antibody-based therapeutics) production. Precise IgG quantification in plasma is a prerequisite for accurate estimation of the purification process efficiency. Although immunoglobulins from HHP have been purified for over a century, there is still no in vitro method for precise and accurate determination of IgG content in HHP. For this reason, the purification process efficiency has been assessed by antibody activity measurements, mostly performed in vivo. Here we describe the development of a precise and accurate in vitro immunoassay for IgG quantification in HHP. We showed and highlighted that any difference in composition of IgG population between the standard and the sample, with respect to both IgG subclass distribution and antigen-specific IgG content, leads to inaccurate IgG quantification. We demonstrated that caprylic acid precipitation as the method for IgG isolation from horse plasma renders the composition of IgG population unchanged. This very efficient, fast, simple and inexpensive method was used to prepare internal, sample- specific reference IgG for each plasma sample, which was tested simultaneously to a respective plasma sample. Deviation of IgG quantity determined by ELISA for each sample-specific reference from its nominal value was used for correction of the results of respective plasma sample, which led to accurate and precise IgG quantification as shown by method validation. The here presented novel concept of sample- specific correction of immunoassay results could be widely applicable and easily introduced in different immunoassays for more accurate and precise plasma IgG quantification.

Antitoxin downstream processing ; Antivenom ; IgG quantification ; Hyperimmune horse plasma ; ELISA ; IgG subclass distribution

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

164

2019.

276-282

objavljeno

0731-7085

1873-264X

10.1016/j.jpba.2018.10.020