Eradication of Intracanal Enterococcus Faecalis Biofilm by Passive Ultrasonic Irrigation and RinsEndo System (CROSBI ID 256347)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Toljan, Ivana ; Bago, Ivona ; Anić, Ivica Eradication of Intracanal Enterococcus Faecalis Biofilm by Passive Ultrasonic Irrigation and RinsEndo System // Acta stomatologica Croatica, 50 (2016), 1; 14-22. doi: 10.15644/asc50/1/3

Podaci o odgovornosti

Toljan, Ivana ; Bago, Ivona ; Anić, Ivica

hrvatski

Eradication of Intracanal Enterococcus Faecalis Biofilm by Passive Ultrasonic Irrigation and RinsEndo System

The aim of the study was to compare the antimicrobial efficacy of three irrigation techniques after the use of standardized volume of NaOCl and with standardized time and irrigation. METHODOLOGY: Forty-eight single rooted teeth were inoculated with an Enterococcus faecalis suspension for 24 h. The remaining six canals served as negative controls. The 36 root canals were randomly distributed into three experimental groups ; group 1, conventional syringe irrigation ; group 2, automated-dynamic irrigation (RinsEndo) ; group 3, passive ultrasonic irrigation (PUI). In the first protocol, the standardized volume of 3% NaOCl (20 mL) was used and in the second protocol, and standardized irrigation time (45 seconds) was used. Samples from root canals were cultured and the colony-forming units (CFUs) were counted. RESULTS: When the volume of the irrigant was standardized, RinsEndo was more effective than PUI (p<0.01). When the irrigation time was standardized, there were no significant differences between any irrigation techniques (p>0.05). The RinsEndo group had the highest percentage of minimal counts of E. faecalis CFUs. CONCLUSIONS: RinsEndo was more effective than PUI only when the volume of the irrigant was standardized. However, the RinsEndo provided higher bacterial reduction in both protocols when using the least amount of the irrigant and providing longer contact time.

korijenski kanal ; ispiranje ; antimikrobno djelovanje

nije evidentirano

engleski

Eradication of Intracanal Enterococcus Faecalis Biofilm by Passive Ultrasonic Irrigation and RinsEndo System

nije evidentirano

root canal ; irrigation ; antimicrobial efficacy