Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides (CROSBI ID 255989)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vladislavić, Nives ; Škugor Rončević Ivana ; Buljac Maša ; Brinić Slobodan ; Krivić Denis ; Buzuk Marijo Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides // Sensors, 18 (2018), 11; 3753, 17. doi: 10.3390/s18113753

Podaci o odgovornosti

Vladislavić, Nives ; Škugor Rončević Ivana ; Buljac Maša ; Brinić Slobodan ; Krivić Denis ; Buzuk Marijo

engleski

Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides

The amperometric determination of cysteine, using an electrode based on ternary silver-copper sulphide, is presented. Electrochemical characterizations (using cyclic voltammetry) of three electrode materials revealed that the electrode based on the material that consists of jalpaite (Ag3CuS2), doped with a small amount of metallic silver, has the best electrocatalytical performance for cysteine oxidation. For the amperometric determination, 0.142 V at pH 5 and 0.04 V at pH 7 vs. Ag/AgCl, related to the electrocatalytical oxidation of thiol group, were chosen. Electrochemical impedance spectroscopy together with Fourier transform infrared spectroscopy (FTIR) revealed that oxidation takes place on the electrode surface with fouling effect, which does not affect a wide linear working range between 1 μM and 100 μM. Sensitivities, at pH 5 and pH 7, are calculated to be 0.11 μA μM-1 and 0.10 μA μM-1, respectively. The detection limits were determined to be 0.036 μM and 0.024 μM for pH 5 and pH 7, respectively. In the presence of uric acid, folic acid, ascorbic acid and glucose no interference was noticed. This electrode showed remarkable stability and excellent reproducibility. The electrode was exploited for the determination of cysteine in a dietary supplement with the excellent recoveries.

cysteine ; determination ; silver-copper sulfides ; amperometry ; electrochemical ; impedance spectroscopy ; FTIR ; electroanalysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

18 (11)

2018.

3753

17

objavljeno

1424-8220

10.3390/s18113753

Povezanost rada

Kemija

Poveznice
Indeksiranost