Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Dual 3D printed material mimicking mechanical behaviour of healthy and aneurysmal arterial tissue (CROSBI ID 666707)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Smoljkić, Marija ; Virag, Lana ; Jurčević, Ante ; Kubik, Kristijan ; Grabić, Ivan ; Godec, Damir ; Karšaj, Igor Dual 3D printed material mimicking mechanical behaviour of healthy and aneurysmal arterial tissue. 2018

Podaci o odgovornosti

Smoljkić, Marija ; Virag, Lana ; Jurčević, Ante ; Kubik, Kristijan ; Grabić, Ivan ; Godec, Damir ; Karšaj, Igor

engleski

Dual 3D printed material mimicking mechanical behaviour of healthy and aneurysmal arterial tissue

A phantom, 3D print from polymer material, can be of great help for applications such as medical device testing, planning of medical treatments, and for educational purposes. The phantom should not only be realistic geometry-wise, but its mechanical response should correspond to the representative mechanical behaviour as well. However, arteries are soft tissues which besides nonlinear and anisotropic behaviour can also undergo large deformations. Mimicking such a complex behaviour is not possible to achieve with a single isotropic polymer material. As 3D printing technology builds an object by successively adding material layer by layer, the material can be defined at the voxel level. A study presented in (Wang et al. 2016) proved the feasibility of 3D printing of mechanically accurate tissue-mimicking phantoms. They indicated that dual-material phantoms can exhibit strain-stiffening behavior characteristic for soft tissues, which can never be achieved by a single polymer material. Despite demonstrating that the mechanical behavior of printed metamaterials can be tuned by changing the design parameters, they did not propose design parameters for any specific tissue. In this study the design of metamaterial will be done by using iterative finite element (FE) simulation. The FE models of a uniaxially loaded segments will be compared with the desired stress-strain response of healthy and aneurysmal intracranial arteries (Scott et al. 1972, Cebral et al. 2015). Orientation and arrangement of the base materials will be iteratively changed until desired behaviour is acquired. Numerically btained design of material, layer-based combination of a different soft and stiff materials, will be 3D printed. In order to confirm realistic behaviour of chosen material in physiological range of stretches, it will be mechanically tested on a uniaxial tensile machine. Experimental stress-strain curves will be compared with the results from the FE simulations and with the experimental data reported in literature. Designed dual material will enable us to approximate a more realistic 3D printed phantom from CT arterial scans.

3D printing, arterial tissue, aneurysm

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

ID-1127

2018.

objavljeno

Podaci o matičnoj publikaciji

Podaci o skupu

10th European Solid Mechanics Conference

predavanje

02.07.2018-06.07.2018

Bologna, Italija

Povezanost rada

Strojarstvo