Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Quantification of free fatty acids in human stratum corneum using tandem mass spectrometry and surrogate analyte approach (CROSBI ID 255035)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Dapić, Irena ; Kobetić, Renata ; Brkljačić, Lidija ; Kezić, Sanja ; Jakasa, Ivone Quantification of free fatty acids in human stratum corneum using tandem mass spectrometry and surrogate analyte approach // Biomedical chromatography, 32 (2018), 2; e4056, 9. doi: 10.1002/bmc.4056

Podaci o odgovornosti

Dapić, Irena ; Kobetić, Renata ; Brkljačić, Lidija ; Kezić, Sanja ; Jakasa, Ivone

engleski

Quantification of free fatty acids in human stratum corneum using tandem mass spectrometry and surrogate analyte approach

The free fatty acids (FFAs) are one of the major components of the lipids in the stratum corneum (SC), the uppermost layer of the skin. Relative composition of FFAs has been proposed as a biomarker of the skin barrier status in patients with atopic dermatitis (AD). Here, we developed an LC‐ESI‐MS/MS method for simultaneous quantification of a range of FFAs with long and very long chain length in the SC collected by adhesive tape (D‐Squame). The method, based on derivatization with 2‐bromo‐1‐methylpyridinium iodide and 3‐carbinol‐1‐methylpyridinium iodide, allowed highly sensitive detection and quantification of FFAs using multiple reaction monitoring. For the quantification, we applied a surrogate analyte approach and internal standardization using isotope labeled derivatives of FFAs. Adhesive tapes showed the presence of several FFAs, which are also present in the SC, a problem encountered in previous studies. Therefore, the levels of FFAs in the SC were corrected using C12:0, which was present on the adhesive tape, but not detected in the SC. The method was applied to SC samples from patients with atopic dermatitis and healthy subjects. Quantification using multiple reaction monitoring allowed sufficient sensitivity to analyze FFAs of chain lengths C16–C28 in the SC collected on only one tape strip.

free fatty acids ; liquid chromatography ; mass spectrometry ; stratum corneum ; surrogate analyte

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

32 (2)

2018.

e4056

9

objavljeno

0269-3879

1099-0801

10.1002/bmc.4056

Povezanost rada

Kemija

Poveznice
Indeksiranost