ELECTROCHEMICAL BEHAVIOR OF MIXED SILVER-COPPER SULFIDE TOWARD H2O2: ANALYTICAL APPLICABILITY FOR BIOSENSING SYSTEMS (CROSBI ID 666276)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Buzuk, Marijo ; Škugor Rončević, Ivana ; Vladislavić, Nives ; Buljac, Maša ELECTROCHEMICAL BEHAVIOR OF MIXED SILVER-COPPER SULFIDE TOWARD H2O2: ANALYTICAL APPLICABILITY FOR BIOSENSING SYSTEMS // Book of abstracts / 25th Congress of the society of chemists and technologists of Macedonia (with international participation) 19-22 / Stafilov, Trajče (ur.). Skopje: Society of Chemists and Technologists of Macedonia, 2018. str. 141-141

Podaci o odgovornosti

Buzuk, Marijo ; Škugor Rončević, Ivana ; Vladislavić, Nives ; Buljac, Maša

hrvatski

ELECTROCHEMICAL BEHAVIOR OF MIXED SILVER-COPPER SULFIDE TOWARD H2O2: ANALYTICAL APPLICABILITY FOR BIOSENSING SYSTEMS

Comparative study of electrochemical behaviors of mixed silver-copper sulfides and silver sulfide has been made in order to investigate its analytical applicability as mediators in biosensing systems (containing oxidases or peroxidases). X-ray diffractometry (XRD) of prepared powder of mixed silver-copper sulfide revealed that beside ternary sulfides (AgCuS and Ag 1.2 Cu 0.8 S) also metallic silver can be found. The electrocatalytical activities of sulfides were evaluated towards the detection of hydrogen peroxide (H 2 O 2 ) at various pH values. Cyclic voltammetry was carried out to determine the exact reduction (0 V) and oxidation (0.25 V) potentials for the electrochemical reaction of H2O2 on carbon paste electrode modified with mixed silver-copper sulfide or silver sulfide. Tentative electrochemical reaction mechanisms for observed phenomenon are proposed. The amperometric studies revealed that the mixed copper-silver sulfide modified carbon paste electrode performed well by attaining a wide linear response range toward H 2 O 2 from 1 µM to 3 mM with detection limit 0.14 µM and the sensitivity of 350 µA mM -1 . In addition, good selectivity, rapid and stable response towards H 2 O 2 is obtained. Obtained results suggest promising paths for selective and sensitive application of sulfide modified electrode in biosensing system.

hydrogen peroxide, silver-copper sulfide, carbon paste, electroanalytical, biosensing.

nije evidentirano

engleski

ELECTROCHEMICAL BEHAVIOR OF MIXED SILVER-COPPER SULFIDE TOWARD H2O2: ANALYTICAL APPLICABILITY FOR BIOSENSING SYSTEMS

nije evidentirano

hydrogen peroxide, silver-copper sulfide, carbon paste, electroanalytical, biosensing.

nije evidentirano

Podaci o prilogu

141-141.

2018.

objavljeno

Podaci o matičnoj publikaciji

Book of abstracts / 25th Congress of the society of chemists and technologists of Macedonia (with international participation) 19-22

Stafilov, Trajče

Skopje: Society of Chemists and Technologists of Macedonia

978-9989-760-16-7

Podaci o skupu

25th Congress of Chemists and Technologists of Macedonia (SCTM 2018)

poster

19.09.2018-22.09.2018

Ohrid, Sjeverna Makedonija

Povezanost rada

Kemija

Poveznice