Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Optimizing the detection of characteristic waves in ECG based on processing methods combinations (CROSBI ID 254319)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Friganović, Krešimir ; Kukolja, Davor ; Jović, Alan ; Cifrek, Mario ; Krstačić, Goran Optimizing the detection of characteristic waves in ECG based on processing methods combinations // IEEE access, 6 (2018), 50609-50626. doi: 10.1109/ACCESS.2018.2869943

Podaci o odgovornosti

Friganović, Krešimir ; Kukolja, Davor ; Jović, Alan ; Cifrek, Mario ; Krstačić, Goran

engleski

Optimizing the detection of characteristic waves in ECG based on processing methods combinations

Accurate detection of characteristic electrocardiogram (ECG) waves is necessary for ECG analysis and interpretation. In this paper, we distinguish four processing steps of detection algorithms: noise and artefacts reduction, transformations, fiducial marks selection of wave candidates, and decision rule. Processing steps combinations from several detection algorithms are used to find QRS, P, and T wave peaks. Additionally, we consider the search window parameter modification based on waveform templates extracted by heart cycles clustering. The methods are extensively evaluated on two public ECG databases containing QRS, P, and T wave peaks annotations. We found that the combination of morphological mathematical filtering with Elgendi's algorithm works best for QRS detection on MIT-BIH Arrhythmia Database (detection error rate (DER = 0.48%, Lead I). The combination of modified Martinez’s PT and wavelet transform (WT) methods gave the best results for P wave peaks detection on both databases, when both leads are considered (MIT- BIH Arrhythmia Database: DER = 32.13%, Lead I, DER = 42.52%, Lead II ; QT Database: DER = 21.23%, Lead I, DER = 26.80%, Lead II). Waveform templates in combination with Martinez's WT obtained the best results for T wave peaks detection on QT Database (DER = 25.15%, Lead II). Our work demonstrates that combining some of the best proposed methods in literature leads to improvements over the original methods for ECG waves detection, while maintaining satisfactory computation times.

ECG, characteristic waves, automatic detection algorithms, clustering, expert system, biomedical signal analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6

2018.

50609-50626

objavljeno

2169-3536

10.1109/ACCESS.2018.2869943

Trošak objave rada u otvorenom pristupu

Povezanost rada

Elektrotehnika, Računarstvo, Kliničke medicinske znanosti

Poveznice
Indeksiranost