Pregled bibliografske jedinice broj: 949175
Brain biopsy performed with the RONNA G3 system: a case study on using a novel robotic navigation device for stereotactic neurosurgery
Brain biopsy performed with the RONNA G3 system: a case study on using a novel robotic navigation device for stereotactic neurosurgery // International journal of medical robotics and computer assisted surgery, 14 (2017), 1; 10.1002/rcs.1884, 7 doi:10.1002/rcs.1884 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 949175 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Brain biopsy performed with the RONNA G3 system: a case study on using a novel robotic navigation device for stereotactic neurosurgery
Autori
Dlaka, Domagoj ; Švaco, Marko ; Chudy, Darko ; Jerbić, Bojan ; Šekoranja, Bojan ; Šuligoj, Filip ; Vidaković, Josip ; Almahariq, Fadi ; Romić, Dominik
Izvornik
International journal of medical robotics and computer assisted surgery (1478-5951) 14
(2017), 1;
10.1002/rcs.1884, 7
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
brain biopsy ; computer‐assisted surgery ; frameless stereotaxy ; robotic neurosurgery ; RONNA G3
Sažetak
Background: Robotic neuronavigation is becoming an important tool for neurosurgeons. Wepresent a case study of a frameless stereotactic biopsy guided by the RONNA G3 roboticneuronavigation system.Methods: A 45 year‐old patient with a history of vertigo, nausea and vomiting was diagnosedwith multiple periventricular lesions. Neurological status was unremarkable. A frameless roboticbiopsy of a brain lesion was performed.Results: Three tissue samples were obtained. There were no intraoperative or postoperativecomplications. Histological analysis showed a B‐cell lymphoma. After merging the preoperativeCT scan with the postoperative MRI and CT scans, the measured error between the plannedand the postoperatively measured entry point was 2.24 mm and the measured error betweenthe planned and postoperatively measured target point was 2.33 mm.Conclusions: The RONNA G3 robotic system was used to navigate a Sedan brain biopsyneedle to take tissue samples and could be a safe and precise tool for brain biopsy.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo
POVEZANOST RADA
Projekti:
HRZZ-IP-2013-11-4192 - Novi koncept primijenjene kognitivne robotike u kliničkoj neuroznanosti (ACRON) (Jerbić, Bojan, HRZZ - 2013-11) ( CroRIS)
Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb
Profili:
Filip Šuligoj
(autor)
Darko Chudy
(autor)
Bojan Šekoranja
(autor)
Bojan Jerbić
(autor)
Josip Vidaković
(autor)
Fadi Almahariq
(autor)
Marko Švaco
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE