Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System


Šuligoj, Filip; Jerbić, Bojan; Šekoranja, Bojan; Vidaković, Josip; Švaco, Marko
Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System // Transactions of FAMENA, 42 (2018), 2; 27-38 doi:10.21278/tof.42203 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 948820 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System

Autori
Šuligoj, Filip ; Jerbić, Bojan ; Šekoranja, Bojan ; Vidaković, Josip ; Švaco, Marko

Izvornik
Transactions of FAMENA (1333-1124) 42 (2018), 2; 27-38

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
medical robotics ; localization strategy ; accuracy ; RONNA

Sažetak
Precise navigation of surgical instruments is one of the most important features of autonomous surgical robots. In this paper, we introduce a concept of robot localization strategy and analyse its influence on the overall application error of a robot system for frameless stereotactic neurosurgery named RONNA. Localization strategies utilize specific angles at which the robot can approach a target point, orientations, and types of movement during the procedure of physical space fiducial marker localization and positioning to the target points. The localization strategies developed in this study are a neutral orientation strategy (NOS), an orientation correction strategy (OCS) and a joint displacement minimization strategy (JDMS). To evaluate the robot positioning performance with the localization strategies applied, we performed laboratory phantom measurements using a different number of fiducial markers in the registration procedure. When three, four, and five fiducial markers were used, the application error for the NOS was 1.571±0.256 mm, 1.397±0.283 mm, and 1.327±0.274 mm, and for the OCS, it was 0.429±0.133 mm, 0.284±0.068mm, and 0.260±0.076 mm, respectively. The application error for the JDMS was 0.493±0.176 mm with four and 0.369±0.160 mm with five fiducial markers used.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
HRZZ-4192

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Poveznice na cjeloviti tekst rada:

doi hrcak.srce.hr

Citiraj ovu publikaciju:

Šuligoj, Filip; Jerbić, Bojan; Šekoranja, Bojan; Vidaković, Josip; Švaco, Marko
Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System // Transactions of FAMENA, 42 (2018), 2; 27-38 doi:10.21278/tof.42203 (međunarodna recenzija, članak, znanstveni)
Šuligoj, F., Jerbić, B., Šekoranja, B., Vidaković, J. & Švaco, M. (2018) Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System. Transactions of FAMENA, 42 (2), 27-38 doi:10.21278/tof.42203.
@article{article, author = {\v{S}uligoj, Filip and Jerbi\'{c}, Bojan and \v{S}ekoranja, Bojan and Vidakovi\'{c}, Josip and \v{S}vaco, Marko}, year = {2018}, pages = {27-38}, DOI = {10.21278/tof.42203}, keywords = {medical robotics, localization strategy, accuracy, RONNA}, journal = {Transactions of FAMENA}, doi = {10.21278/tof.42203}, volume = {42}, number = {2}, issn = {1333-1124}, title = {Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System}, keyword = {medical robotics, localization strategy, accuracy, RONNA} }
@article{article, author = {\v{S}uligoj, Filip and Jerbi\'{c}, Bojan and \v{S}ekoranja, Bojan and Vidakovi\'{c}, Josip and \v{S}vaco, Marko}, year = {2018}, pages = {27-38}, DOI = {10.21278/tof.42203}, keywords = {medical robotics, localization strategy, accuracy, RONNA}, journal = {Transactions of FAMENA}, doi = {10.21278/tof.42203}, volume = {42}, number = {2}, issn = {1333-1124}, title = {Influence of the Localization Strategy on the Accuracy of a Neurosurgical Robot System}, keyword = {medical robotics, localization strategy, accuracy, RONNA} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus