Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Three phase transformer grounding influence analysis on inrush current (CROSBI ID 663341)

Prilog sa skupa u zborniku | prošireni sažetak izlaganja sa skupa

Špoljarić, Željko ; Jerković Štil, Vedrana ; Hederić, Željko Three phase transformer grounding influence analysis on inrush current // DIGEST BOOK OF THE SEVENTH SYMPOSIUM ON APPLIED ELECTROMAGNETICS SAEM'18 / Seme, Sebastijan ; Hadžiselimović, Miralem ; Štumberger, Bojan (ur.). Maribor: Univerzitetna založba Univerze v Mariboru, 2018. str. 25-26 doi: 10.18690/978-961-286-171-1

Podaci o odgovornosti

Špoljarić, Željko ; Jerković Štil, Vedrana ; Hederić, Željko

engleski

Three phase transformer grounding influence analysis on inrush current

The main object of research is analysis of grounding influence of three phase transformer on inrush current which occurs during switching of unloaded transformer on to electric grid. Inrush current analysis covers the area of transition behaviour of power transformers. For this purpose, a simulation model shown in Fig. 1 is developed [1]. The model can be used for determination of inrush current amplitude, time of duration and Fourier higher harmonics analysis of power transformers with different voltage level, power and connection. The main idea of model possibilities is given in [2]. Basics inrush current analysis, calculation and measurement is given in [3, 4]. Problems which inrush current can cause is given in [5]. As mentioned, type of transformer grounding can have influence on inrush current amplitude, duration, higher harmonic content and THD factor (Total Harmonic Disorder). Results of analysis on example of one power transformer (250 kVA, 20/0, 42 kV, Yz5) for cases of direct grounding, grounding through various resistances and isolated grounding will be shown.

three phase transformer ; inrush current ; grounding influence

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

25-26.

2018.

objavljeno

10.18690/978-961-286-171-1

Podaci o matičnoj publikaciji

DIGEST BOOK OF THE SEVENTH SYMPOSIUM ON APPLIED ELECTROMAGNETICS SAEM'18

Seme, Sebastijan ; Hadžiselimović, Miralem ; Štumberger, Bojan

Maribor: Univerzitetna založba Univerze v Mariboru

978-961-286-171-1

Podaci o skupu

7th International Symposium on Applied Electromagnetics (SAEM 18)

predavanje

17.06.2018-20.06.2018

Podčetrtek, Slovenija

Povezanost rada

Trošak objave rada u otvorenom pristupu

Elektrotehnika

Poveznice