Grgić, Davor ; Vlahović, Štefica ; Matijević, Mario ; Dučkić, Paulina ; Špalj, Srđan Dose Calculation for Emergency Control Room HVAC Filter // 12th International Conference of the Croatian Nuclear Society Conference Proceedings / Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica (ur.). Zagreb: Hrvatsko nuklearno društvo, 2018. str. S7173-1-S7173-14

Podaci o odgovornosti

Grgić, Davor ; Vlahović, Štefica ; Matijević, Mario ; Dučkić, Paulina ; Špalj, Srđan

engleski

Dose Calculation for Emergency Control Room HVAC Filter

NPP Krsko is introducing Emergency Control Room (ECR) as part of safety upgrades. According to 10CFR50 Appendix A, GDC 19, both main control room and emergency control room should have adequate radiation protection to permit operators to shutdown the plant and keep it in safe shutdown conditions without receiving more than 50 mSv effective whole body dose, within 30 days from accident initiation. One of the important prerequisites to achieve that is proper operation of control room HVAC. In this work we are focused to calculation of gamma doses from radioactive materials accumulated in HEPA and charcoal filters during 30 days of HVAC operation. The dose at selected points around the filter was calculated using Microshield 10.0 point kernel code. The radioactive gamma source is calculated using RADTRAD 3.03 for plant’s severe accident SGTR sequence calculated with MAAP 4.0.7 code. Calculated dose rates at peak filter activity are compared against results obtained with SCALE 6.2 MAVRIC shielding sequence (Monaco Monte Carlo functional module and CADIS methodology). The reasonable agreement between point kernel and hybrid Monte Carlo results was obtained.

Emergency Control Room, HVAC filter, gamma dose, point kernel, Monte Carlo

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

S7173-1-S7173-14.

2018.

objavljeno

Podaci o matičnoj publikaciji

12th International Conference of the Croatian Nuclear Society Conference Proceedings

Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica

Zagreb: Hrvatsko nuklearno društvo

978-953-48100-0-2

Podaci o skupu

12th International Conference of the Croatian Nuclear Society

predavanje

03.07.2018-06.07.2018

Zadar, Hrvatska

Povezanost rada

nije evidentirano