Gao, Yueming ; Zhang, Hengfei ; Lin, Shi ; Jiang, Rui-Xin ; Chen, Zhi-Ying ; Lučev Vasić, Željka ; Vai, Mang-I ; Du, Min ; Cifrek, Mario ; Pun, Sio- Hang Electrical exposure analysis of galvanic-coupled intra-body communication based on the empirical arm models // Biomedical engineering online, 17 (2018), 71; 1-16. doi: 10.1186/s12938-018-0473-9

Podaci o odgovornosti

Gao, Yueming ; Zhang, Hengfei ; Lin, Shi ; Jiang, Rui-Xin ; Chen, Zhi-Ying ; Lučev Vasić, Željka ; Vai, Mang-I ; Du, Min ; Cifrek, Mario ; Pun, Sio- Hang

engleski

Electrical exposure analysis of galvanic-coupled intra-body communication based on the empirical arm models

Background: Intra-body communication (IBC) is one of the highlights in studies of body area networks. The existing IBC studies mainly focus on human channel characteristics of the physical layer, transceiver design for the application, and the protocol design for the networks. However, there are few safety analysis studies of the IBC electrical signals, especially for the galvanic-coupled type. Besides, the human channel model used in most of the studies is just a multi-layer homocentric cylinder model, which cannot accurately approximate the real human tissue layer. Conclusion: Based on the empirical arm models established in this paper, we came to conclusion that the frequency of 100–300 kHz which belong to LF (30– 300 kHz) according to the ICNIRP guidelines can be considered as the frequency restrictions of the galvanic-coupled IBC signal. This provided more choices for both intensities of current and voltage signals as well. On the other hand, it also makes great convenience for the design of transceiver hardware and artificial intelligence application. With the frequency restrictions settled, the intensity restrictions that the current signal of 1–10 mA and the voltage signal of 1–2 V were accessible. Particularly, in practical application we recommended the use of the current signals for its broad application and lower impact on the human tissue. In addition, it is noteworthy that the coupling structure design of the electrode interface should attract attention.

Galvanic-coupled intra-body communication ; Empirical arm models ; ICNIRP guidelines ; Electric field intensity ; SAR ; Exposure restrictions

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

17 (71)

2018.

1-16

objavljeno

1475-925X

10.1186/s12938-018-0473-9