Realization and traceability of AC power standard at frequency of 50 Hz (CROSBI ID 662686)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Leniček, Ivan
engleski
Realization and traceability of AC power standard at frequency of 50 Hz
An AC power standard for traceable calibration of reference power and energy meters has been established in Primary electromagnetic laboratory PEL, the national calibration laboratory for electrical quantities in Croatia. The standard uses synchronous sampling technique for signal generation and measurement, driven by single digital voltmeter. Traceability of power to national standards has been achieved through validation of sampling-based AC voltage measurement with AC-DC voltage transfer method. The realized AC power standard is covered with expanded standard uncertainty of 25 ppm at frequency of 50 Hz.
AC power standard, traceability, digital sampling, digital voltmeter
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
122-126.
2018.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018)
Ivšić, Branimir ; Jurčević, Marko
Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu
978-953-184-234-1
Podaci o skupu
First International Colloquium on Smart Grid Metrology (SmaGriMet 2018)
poster
24.04.2018-27.04.2018
Split, Hrvatska