Constrained field-oriented control of permanent magnet synchronous machine with field-weakening utilizing a reference governor (CROSBI ID 251793)

Prilog u časopisu | pregledni rad (znanstveni) | međunarodna recenzija

Jerčić, Tino ; Ileš, Šandor ; Žarko, Damir ; Matuško, Jadranko Constrained field-oriented control of permanent magnet synchronous machine with field-weakening utilizing a reference governor // Automatika : časopis za automatiku, mjerenje, elektroniku, računarstvo i komunikacije, 58 (2018), 4; 439-449. doi: 10.1080/00051144.2018.1453441

Podaci o odgovornosti

Jerčić, Tino ; Ileš, Šandor ; Žarko, Damir ; Matuško, Jadranko

engleski

Constrained field-oriented control of permanent magnet synchronous machine with field-weakening utilizing a reference governor

This paper presents a complete solution for constrained control of a permanent magnet synchronous machine. It utilizes field-oriented control with proportional-integral current controllers tuned to obtain a fast transient response and zero steady-state error. To ensure constraint satisfaction in the steady state, a novel field-weakening algorithm which is robust to flux linkage uncertainty is introduced. Field weakening problem is formulated as an optimization problem which is solved online using projected fast gradient method. To ensure constraint satisfaction during current transients, an additional device called current reference governor is added to the existing control loops. The constraint satisfaction is achieved by altering the reference signal. The reference governor is formulated as a simple optimization problem whose objective is to minimize the difference between the true reference and a modified one. The proposed method is implemented on Texas instruments F28343 200 MHz microcontroller and experimentally verified on a surface mounted permanent magnet synchronous machine.

Permanent magnet machines ; vector control ; optimization ; PI control ; nonlinear control systems ; field weakening

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

58 (4)

2018.

439-449

objavljeno

0005-1144

1848-3380

10.1080/00051144.2018.1453441

Povezanost rada

Elektrotehnika, Temeljne tehničke znanosti

Poveznice
Indeksiranost