Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Exploration of buried carbonate aquifers by the inverse and forward modelling of the Controlled Source Audio-Magnetotelluric data (CROSBI ID 250803)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šumanovac, Franjo ; Orešković, Jasna Exploration of buried carbonate aquifers by the inverse and forward modelling of the Controlled Source Audio-Magnetotelluric data // Journal of applied geophysics, 153 (2018), 47-63. doi: 10.1016/j.jappgeo.2018.04.007

Podaci o odgovornosti

Šumanovac, Franjo ; Orešković, Jasna

engleski

Exploration of buried carbonate aquifers by the inverse and forward modelling of the Controlled Source Audio-Magnetotelluric data

On the selected cases, Gotalovec in the area of Pannonian basin and Baška in the Dinaridic karst area, that are representing a common hydrogeological model in both regions of Croatia, CSAMT data together with data of other geophysical methods (electrical resistivity tomography, electrical sounding and seismic reflection) enabled the definition of a reliable prognostic geological model. The model consists of carbonate aquifer which underlies an impermeable thick package of clastic deposits. There are great variations of the dolomitic aquifer depths in the Gotalovec area due to strong tectonic activity, while in the Baška area depth changes are caused by the layer folding. The CSAMT method provides the most complete data on lithological and structural relationships in cases of hydrogeological targets deeper than 100 m. Based on the presented models we can conclude that the CSAMT method can provide greater exploration depth than electrical resistivity tomography (ERT) and can be considered as a fundamental geophysical method for exploration of buried carbonate aquifers, deeper than 100 m. But, the CSAMT research may demonstrate its advantages only in the case of very dense layout of CSAMT stations (25-50 m), due to the greater sensitivity to noise in relation to resistivity methods. Interpretation of CSAMT data is more complex in relation to resistivity methods, and a forward modelling method sometimes gives better results than an inversion due to possibility of the use of additional data acquired by other geophysical methods (ERT, electrical sounding and seismic reflection). At greater depths, the resolution of all electrical methods including the CSAMT method is significantly reduced, and seismic reflection can be very useful to resolve deeper lithological interfaces.

CSAMT ; groundwater ; carbonate aquifer ; forward modelling ; inversion

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

153

2018.

47-63

objavljeno

0926-9851

1879-1859

10.1016/j.jappgeo.2018.04.007

Povezanost rada

Geologija, Rudarstvo, nafta i geološko inženjerstvo

Poveznice
Indeksiranost