Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Estimate of dynamic change of fluid saturation during CO2 injection — Case study of a regional aquifer in Croatia (CROSBI ID 249924)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vulin, Domagoj ; Saftić, Bruno ; Macenić, Marija Estimate of dynamic change of fluid saturation during CO2 injection — Case study of a regional aquifer in Croatia // Interpretation (Tulsa), 6 (2018), 1; SB51-SB64. doi: 10.1190/int-2017-0077.1

Podaci o odgovornosti

Vulin, Domagoj ; Saftić, Bruno ; Macenić, Marija

engleski

Estimate of dynamic change of fluid saturation during CO2 injection — Case study of a regional aquifer in Croatia

Total carbon dioxide (CO2) storage capacities are estimated in numerous studies, but there is a lack of research of possible injection rates at a particular site. We have performed compositional simulation with permeability variation (based on log-normal distribution parameters of the measured data from similar formations in an oil field above the aquifer) to include changes of aqueous and gaseous phase properties (composition, viscosities, density), and heterogeneity of a regional CO2 storage site. We have performed sensitivity tests on vertical permeability multiplier, different grid block sizes, diffusivity, and capillary pressures to detect the key parameters for injectivity and storage efficiency. In this way, we modeled heterogeneity of a CO2 storage site and the possible injection rate in this detail for the first time. Based on pressure analysis in simulation cases, we found that it will be hard to avoid fracturing the near- wellbore zone, but fracturing these zones might also increase the injectivity, and this can still be done without damaging the cap rock. Simulation results indicated that maximum pressure will occur in zones above wellbores at the short period after the injection, and almost no change of average pressure in the regional aquifer will be noticeable, which leads to the conclusion that the total (theoretical) storage capacity is not the key issue for CO2 storage in aquifers and that injectivity for the storage site (expressed as the rate) should be the key parameter for selecting the pilots for CO2 storage.

sequestration, heterogeneous, aquifer

Glavni autor: Vulin, D.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (1)

2018.

SB51-SB64

objavljeno

2324-8858

10.1190/int-2017-0077.1

Povezanost rada

Rudarstvo, nafta i geološko inženjerstvo

Poveznice