Design of Oil-Free Pump with Negligible Internal Volume (CROSBI ID 485672)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Obsieger, Boris ; Obsieger, Josip Design of Oil-Free Pump with Negligible Internal Volume // Zerp Leakage - Minimum Charge / Pridasawas, Wimolsiri; Palm Björn (ur.). Stockholm: Royal Institute of Technology, Stockholm, 2002. str. C11-x

Podaci o odgovornosti

Obsieger, Boris ; Obsieger, Josip

engleski

Design of Oil-Free Pump with Negligible Internal Volume

Design of hydrodynamic pump with negligible internal volume is carried out by modification of Rayleight's hydrodynamic step slider on which the outflow recess is cut near to step. It can be used in various refrigerating systems, as those using working mixture lithium bromide-water in absorption cycle. In comparison to the frequently used volumetric pumps, hydrodynamic pumps are simple and cheap devices which sliding surfaces are lubricated directly by working mixture, regardless of its type. Since the ratio of dimensions of hydrodynamic pumps seriously influence its efficiency, the proposed design is based on criteria of minimal driving power.

hydrodynamic pump; refrigerating systems; lithium bromide-water

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

C11-x.

2002.

objavljeno

Podaci o matičnoj publikaciji

Zerp Leakage - Minimum Charge

Pridasawas, Wimolsiri; Palm Björn

Stockholm: Royal Institute of Technology, Stockholm

Podaci o skupu

Zerp Leakage - Minimum Charge

predavanje

25.08.2002-29.08.2002

Stockholm, Švedska

Povezanost rada

Strojarstvo