Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Analysis of Spent Fuel Pool Loss of Coolant Inventory Accident Progression (CROSBI ID 248417)

Prilog u časopisu | izvorni znanstveni rad

Đaković, Josip ; Grgić, Davor Analysis of Spent Fuel Pool Loss of Coolant Inventory Accident Progression // Energija : časopis Hrvatske elektroprivrede, 66 (2017), S.I.; 99-107

Podaci o odgovornosti

Đaković, Josip ; Grgić, Davor

engleski

Analysis of Spent Fuel Pool Loss of Coolant Inventory Accident Progression

The Spent Fuel Pool (SFP) in a nuclear power plant is a robust structure designed to withstand large seismic loads. After the terrorist attacks on September 11 and the accident in the Fukushima nuclear power plant, special attention was focused on safety assessments and taking measures to mitigate possible accidents related to the spent fuel pool. This paper will provide an insight into spent fuel pool loss of coolant phenomenology and consequence mitigation strategies. Model of NPP Krško SFP was presented in MELCOR code which has been used as a case-study for evaluating accident propagation. The calculations were carried out using the latest version of MELCOR code which was updated for the analysis of severe accidents in nuclear spent fuel pools.

Spent Fuel Pool ; Loss of Coolant accident ; fuel heatup, cladding oxidation, decay heat, NPP Krško

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

66 (S.I.)

2017.

99-107

objavljeno

0013-7448

1849-0751

Povezanost rada

Elektrotehnika