Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

MIPO of proximal humerus fractures through an anterolateral acromial approach. Is the axillary nerve at risk? (CROSBI ID 248146)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Knežević, Josip ; Mihalj, Mario ; Čukelj, Fabijan ; Ivanišević, Arsen MIPO of proximal humerus fractures through an anterolateral acromial approach. Is the axillary nerve at risk? // Injury, 48 (2017), S5; S15-S20. doi: 10.1016/S0020-1383(17)30733-7

Podaci o odgovornosti

Knežević, Josip ; Mihalj, Mario ; Čukelj, Fabijan ; Ivanišević, Arsen

engleski

MIPO of proximal humerus fractures through an anterolateral acromial approach. Is the axillary nerve at risk?

It is known that shoulder surgery may cause iatrogenic injury to the axillary nerve as a serious complication, but there is little evidence to indicate whether the axillary nerve is at risk of injury during an anterolateral acromial approach for minimally-invasive plate osteosynthesis (MIPO) of proximal humerus fractures. We hypothesised that this surgical method is safe for the axillary nerve and would preserve it from iatrogenic injury. We conducted a prospective follow-up cohort study on 49 consecutive patients with proximal humerus fractures who were managed with MIPO through an anterolateral approach. All patients underwent standardised electroneurographic testing, with assessment of amplitudes of evoked compound muscle action potentials (CMAP) and distal motor latencies (DML) of the axillary nerves, pre- and post-operatively. Six weeks after injury, all patients underwent needle electromyographic (EMG) testing of anterior, middle, posterior deltoid, teres minor and paraspinal muscles for detecting abnormal muscle activity as a sign of acute denervation. After six months of physical rehabilitation, patients with axillary nerve injury underwent control electroneurographic testing to check the recovery of neurographic features (CMAP, DML). All nerve measurements were compared to reference values, and between right and left side. Results Five patients had a mild-to-moderate traumatic axillary nerve injury before surgery. There were no significant differences between amplitudes of CMAP (p = 0.575) and DML (p = 0.857) pre- and post-surgical procedure. These results confirmed safety of this surgical method in the preservation of axillary nerve from iatrogenic injury, but the course of the axillary nerve must be kept in mind.

axillary nerve, proximal humerus, nerve injury, MIPO, locking plate, electromyoneurography

This supplement - "Clinical and anatomical studies" - was supported by the Croatian Trauma Society ; Bore Bakota (Ed.) ; (S1-S72).

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

48 (S5)

2017.

S15-S20

objavljeno

0020-1383

1879-0267

10.1016/S0020-1383(17)30733-7

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost