Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

X-ray protection in pediatric radiology with special view on respiratory tract (CROSBI ID 658362)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Milković, Đurđica ; Ranogajec-Komor, Maria ; Batinić, Danica X-ray protection in pediatric radiology with special view on respiratory tract // European journal of pediatrics. 2017. str. 1552-1552

Podaci o odgovornosti

Milković, Đurđica ; Ranogajec-Komor, Maria ; Batinić, Danica

engleski

X-ray protection in pediatric radiology with special view on respiratory tract

Background: There is permanently growing demand in diagnostic radiological procedures in pediatrics. Important issue is to know precisely effects of dose radiation in children. Objective was to investigate effect of low dose radiation during X-ray examination of chest in children. Methods X-ray of chest was eximinated in patients and phantoms. The influence of low doses of radiation on chest and other organs, as well as effect of working method and human factor were analysed. Measurements were done with termoluminiscent dosimeters (TL) and radiophotoluminiscent dosimeters (RPL) adopted to age of children. Babies and small children were exposed in baby-fix and rotation chair, and older children stand in front of camera. The doses were measured in and on phantom (size of 3 years old child) too.The doses were compared with those of patients. Also, were investigated potential DNA damage. Results: Mean value X-ray dose in primary beam on chest x-ray in patients was 0.26 mSv ± 0.11mSv and in phantom 0.66 ± 0.17 mSv. Correlation was found between doses in primary beam and DNA damage. We found corelation between working method of technicans and X-ray doses too. Conclusion. Our long term work shows importance of permanent dosimetry in X-ray diagnostics in children. Continuous eduaction and good teamwork for dose reduction to minimize the potential damage is necessary to maintain the optimal benefit for patients especially children and medical staff too.

X-ray protection ; children ; respiratory tract

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1552-1552.

2017.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

European journal of pediatrics

0340-6199

1432-1076

Podaci o skupu

EAP 2017 Congress and MasterCourse

poster

12.10.2017-15.10.2017

Ljubljana, Slovenija

Povezanost rada

Kliničke medicinske znanosti

Indeksiranost