Visual assessment of hemolysis affects patient safety (CROSBI ID 246112)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Lukšić, Ana Helena ; Nikolac Gabaj, Nora ; Miler, Marijana ; Dukić, Lora ; Bakliža, Ana ; Šimundić, Ana-Maria Visual assessment of hemolysis affects patient safety // Clinical chemistry and laboratory medicine, 56 (2018), 4; 574-581. doi: 10.1515/cclm-2017-0532

Podaci o odgovornosti

Lukšić, Ana Helena ; Nikolac Gabaj, Nora ; Miler, Marijana ; Dukić, Lora ; Bakliža, Ana ; Šimundić, Ana-Maria

engleski

Visual assessment of hemolysis affects patient safety

BACKGROUND: Manual handling of hemolyzed samples is not standardized and is vulnerable to errors. This study aimed to evaluate laboratory errors due to manual handling of hemolyzed samples and to assess the risk they might have for patient safety. METHODS: Data were retrospectively obtained from a laboratory information system for 25 emergency tests from hemolyzed samples. Hemolysis (concentration of free hemoglobin >0.5 g/L) was visually assessed by comparison with a color chart. The reference person reestimated the routinely assessed degree of hemolysis to all samples (n=3185) received in the laboratory in a 1-week period. For each test, the correct and incorrect way of handling results was determined. Risk assessment was performed according to ISO 14971 standard with five categories of risk (S1- S5) and error occurrence (O1-O5). RESULTS: In the studied period, the emergency laboratory received 495 hemolyzed samples (15.5%) with a total of 2518 laboratory test requests (15.5%): 102 (20.6%) of the reports from hemolyzed samples had a comment on hemolysis ; 31% of the test results were handled incorrectly (20.7% due to the incorrect release of the test result despite hemolysis interference and 10.3% due to unnecessary suppression), accounting for 4.8% of the total test volume. Tests with the highest combination of risk and occurrence rate were troponin T, potassium and total bilirubin. CONCLUSIONS: Manual handling of hemolyzed samples may lead to risk of errors in reporting results for troponin T, potassium and total bilirubin, which may have an effect on clinical decision. In addition, unnecessary suppression of the sample results unaffected by hemolysis could affect patient outcome

hemolysis ; patient safety ; risk assessment ; visual assessment of hemolysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

56 (4)

2018.

574-581

objavljeno

1434-6621

1437-4331

10.1515/cclm-2017-0532

Povezanost rada

Temeljne medicinske znanosti, Kliničke medicinske znanosti

Poveznice
Indeksiranost