Buzov, Ante ; Radnić, Jure ; Grgić, Nikola ; Baloević, Goran Effect of the joint type on the bearing capacity of a multi–drum column under static load // International journal of architectural heritage, 12 (2018), 1; 137-152. doi: 10.1080/15583058.2017.1396380

Podaci o odgovornosti

Buzov, Ante ; Radnić, Jure ; Grgić, Nikola ; Baloević, Goran

engleski

Effect of the joint type on the bearing capacity of a multi–drum column under static load

The results of an experimental study on the effect of the joints between the blocks on the ultimate bearing capacity of a multi-drum column loaded to centric vertical force and horizontal force in the middle of its height are shown. The column is approximately 2.5 m high, with one hinge at the top and another hinge at the bottom. Four types of joints between the blocks were considered: a dry joint (column C-DJ) and joints with stone powder (column C-SPJ), lead (column C-PBJ), and epoxy (column C-EPJ). The applied vertical and horizontal forces, horizontal displacement, vertical strains, and horizontal circumferential strains in the middle of the column height, as well as shortening of the column, were measured. Under axial compression, ratios between the ultimate load bearing capacities of tested columns were C-EPJ: C-DJ: C-SPJ: C-PBJ = 1: 0.68: 0.59: 0.51. The bearing capacity of the tested columns with regard to the horizontal force depended on the level of the applied centric compression force. Columns with soft joints (C-PBJ, C-SPJ) had the largest shortening and the largest horizontal displacements for the equal forces.

bearing capacity ; deformability ; joint effect ; multi-drum column ; static load

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

12 (1)

2018.

137-152

objavljeno

1558-3058

10.1080/15583058.2017.1396380

Povezanost rada

Građevinarstvo

Poveznice
Indeksiranost