Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

A new automated flow cytometer for high frequency in situ characterisation of heterotrophic microorganisms and their dynamics in aquatic ecosystems (CROSBI ID 655981)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Šilović, Tina ; Grégori, Gérald ; Dugenne, Mathilde ; Thyssen, Melilotus ; Calendreau, François ; Cossart, Thibaut ; Kools, Harrie ; Dubelaar, George ; Denis, Michel A new automated flow cytometer for high frequency in situ characterisation of heterotrophic microorganisms and their dynamics in aquatic ecosystems // IMEKO TC19 Workshop on METROLOGY FOR THE SEA: Proceedings. Napulj, 2017. str. 58-61

Podaci o odgovornosti

Šilović, Tina ; Grégori, Gérald ; Dugenne, Mathilde ; Thyssen, Melilotus ; Calendreau, François ; Cossart, Thibaut ; Kools, Harrie ; Dubelaar, George ; Denis, Michel

engleski

A new automated flow cytometer for high frequency in situ characterisation of heterotrophic microorganisms and their dynamics in aquatic ecosystems

Heterotrophic microorganisms represent the main consumers and mineralisers of the organic matter in the ocean as well as in inland waters. These organisms are in strong interaction with phytoplankton and higher trophic levels and may react quickly to environmental changes. In contrast with phytoplankton, due to the lack of photosynthetic pigments they do not naturally emit fluorescence, which makes more complex their analysis by flow cytometry, and consequently, their dynamics at short time and spatial scales are poorly documented. To fill this gap and extend high frequency observation capacity of flow cytometry (FC) to heterotrophic microorganisms, an automated staining module was designed and now equips a Cytosense flow cytometer to perform in situ automated sampling and analysis. Here we describe the first results got with this device and demonstrate the capacity of this new FC instrument to analyse heterotrophic prokaryotes dynamics at high frequency. In a successful experiment, this prototype yielded an extensive data set generated by automated analyses run every 2 hours over 7 days in the frame of a mesocosm investigation addressing natural marine communities.

flow cytometry ; heterotrophic microorganisms

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

58-61.

2017.

objavljeno

Podaci o matičnoj publikaciji

IMEKO TC19 Workshop on METROLOGY FOR THE SEA: Proceedings

Napulj:

Podaci o skupu

IMEKO TC19 WORKSHOP ON METROLOGY FOR THE SEA: “Learning to measure sea health parameters”

predavanje

11.10.2017-13.10.2017

Napulj, Italija

Povezanost rada

Interdisciplinarne prirodne znanosti

Poveznice