Spin-label W-band EPR with Seven-Loop–Six-Gap Resonator: Application to Lens Membranes Derived from Eyes of a Single Donor (CROSBI ID 245132)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Mainali, Laxman ; Sidabras, Jason W. ; Camenisch, Theodore G. ; Ratke, Joseph J. ; Raguz, Marija ; Hyde, James S. ; Subczynski, Witold K. Spin-label W-band EPR with Seven-Loop–Six-Gap Resonator: Application to Lens Membranes Derived from Eyes of a Single Donor // Applied magnetic resonance, 45 (2014), 12; 1343-1358. doi: 10.1007/s00723-014-0578-7

Podaci o odgovornosti

Mainali, Laxman ; Sidabras, Jason W. ; Camenisch, Theodore G. ; Ratke, Joseph J. ; Raguz, Marija ; Hyde, James S. ; Subczynski, Witold K.

engleski

Spin-label W-band EPR with Seven-Loop–Six-Gap Resonator: Application to Lens Membranes Derived from Eyes of a Single Donor

Spin-label W-band (94 GHz) EPR with a five-loop- four-gap resonator (LGR) was successfully applied to study membrane properties (L. Mainali, J.S. Hyde, W.K. Subczynski, Using spin-label W-band EPR to study membrane fluidity in samples of small volume, J. Magn. Reson. 226 (2013) 35-44). In that study, samples were equilibrated with the selected gas mixture outside the resonator in a sample volume ~100 times larger than the sensitive volume of the LGR and transferred to the resonator in a quartz capillary. A seven-loop-six-gap W-band resonator has been developed. This resonator permits measurements on aqueous samples of 150 nL volume positioned in a polytetrafluoroethylene (PTFE) gas permeable sample tube. Samples can be promptly deoxygenated or equilibrated with an air/nitrogen mixture inside the resonator, which is significant in saturation-recovery measurements and in spin-label oximetry. This approach was tested for lens lipid membranes derived from lipids extracted from two porcine lenses (single donor). Profiles of membrane fluidity and the oxygen transport parameter were obtained from saturation-recovery EPR using phospholipid analog spin-labels. Cholesterol analog spin-labels allowed discrimination of the cholesterol bilayer domain and acquisition of oxygen transport parameter profiles across this domain. Results were compared with those obtained previously for membranes derived from a pool of 100 lenses. Results demonstrate that EPR at W-band can be successfully used to study aqueous biological samples of small volume under controlled oxygen concentration.

Eye lens ; Loop-gap resonator ; Membrane ; Saturation recovery ; Spin-label ; W-band

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

45 (12)

2014.

1343-1358

objavljeno

0937-9347

10.1007/s00723-014-0578-7

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Fizika

Poveznice
Indeksiranost