Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Single-channel Sparse Nonnegative Blind Source Separation Method for Automatic 3D Delineation of Lung Tumor in PET Images (CROSBI ID 244262)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kopriva, Ivica ; Ju, Wei ; Zhang, Bin ; Shi, Fei ; Xiang, Dehui ; Yu, Kai ; Wang, Ximing ; Bagci, Ulas ; Chen, Xinjian Single-channel Sparse Nonnegative Blind Source Separation Method for Automatic 3D Delineation of Lung Tumor in PET Images // IEEE Journal of Biomedical and Health Informatics, 21 (2017), 6; 1656-1666. doi: 10.1109/JBHI.2016.2624798

Podaci o odgovornosti

Kopriva, Ivica ; Ju, Wei ; Zhang, Bin ; Shi, Fei ; Xiang, Dehui ; Yu, Kai ; Wang, Ximing ; Bagci, Ulas ; Chen, Xinjian

engleski

Single-channel Sparse Nonnegative Blind Source Separation Method for Automatic 3D Delineation of Lung Tumor in PET Images

In this paper, we propose a novel method for single-channel blind separation of non- overlapped sources and, to the best of our knowledge, apply it for the first time to automatic segmentation of lung tumors in Positron Emission Tomography (PET) images. Our approach first converts 3D PET image into a pseudo multichannel image. Afterwards, regularization free sparseness constrained nonnegative matrix factorization is used to separate tumor from other tissues. By using complexity based criterion, we select tumor component as the one with minimal complexity. We have compared the proposed method with threshold based on 40% and 50% maximum standardized uptake value (SUV), graph cuts (GC), random walks (RW) and affinity propagation (AP) algorithms on 18 non-small cell lung cancer datasets with respect to ground truth provided by two radiologists. Dice similarity coefficient averaged with respect to two ground truths is: 0.780.12 by the proposed algorithm, 0.780.1 by GC, 0.770.13 by AP, 0.770.07 by RW, and 0.750.13 by 50% maximum SUV threshold. Since the proposed method achieved performance comparable with interactive methods, considering the unique challenges of lung tumor segmentation from PET images, our findings support possibility of using our fully automated method in routine clinics. The source codes will be available at www.mipav.net/English/research/research.html .

Single-channel blind source separation ; nonnegative matrix factorization ; sparseness ; lung tumor delineation ; positron emission tomography (PET)

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

21 (6)

2017.

1656-1666

objavljeno

2168-2194

2168-2208

10.1109/JBHI.2016.2624798

Trošak objave rada u otvorenom pristupu

Povezanost rada

Matematika, Računarstvo, Kliničke medicinske znanosti

Poveznice
Indeksiranost