Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Periodontal evaluation of stock and custom cad/cam implant abutments: 1- year follow- up study (CROSBI ID 652801)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Pelivan, Ivica ; Šeparović, Ivan ; Dulčić, Nikša ; Gabrić, Dragana ; Sović, Slavica Periodontal evaluation of stock and custom cad/cam implant abutments: 1- year follow- up study // Clinical oral implants research / Heitz-Mayfield Lisa J. A. (ur.). 2017. str. 243-243

Podaci o odgovornosti

Pelivan, Ivica ; Šeparović, Ivan ; Dulčić, Nikša ; Gabrić, Dragana ; Sović, Slavica

engleski

Periodontal evaluation of stock and custom cad/cam implant abutments: 1- year follow- up study

Background : Implant abutment selection is the crucial moment in implant prosthodontics treatment. Abutments can generally be divided into two main groups: stock and custom. For several years, stock abutments have been the only option available for clinicians. Custom made CAD/CAM abutment acts as adequate support for soft tissues, and the connection between abutment and a cement- retained crown is moved more towards coronal, which makes residual cement removal easier during cementation of a prosthetic restoration. Aim/Hypothesis : The aim of this study was to compare stock and individual CAD/CAM abutments after one year in function. A total of 64 subjects with one missing tooth, were included in this study. The missing tooth was replaced with a dental implant, an abutment and a porcelainfused- to- metal crown. Material and Methods : A total of 64 subjects had a single tooth loss restored by dental implant and porcelain- fused- to- metal crowns were fabricated. In one group there were a total of 34 stock Ti abutments and in the second group of subjects 30 CAD/CAM made Ti abutments. Examination of soft tissues around dental implants included determination of modified plaque index (mPI) and modified bleeding index (mBI), as well as measurement of sulcus probing depth (PPD). The average modified plaque index (mAPI) was calculated from the measured values, as the average measurement value on all four crown surfaces. The average modified bleeding index (mABI) was calculated in the same way. PPD measurement was performed on the mesial, distal, vestibular and lingual crown surface, and the average values of measured probing depth (APPD) were calculated. The values mAPI, mABI and APPD were measured during the first check- up (a week after cementing the crown) and at check- ups after 4, 8 and 12 months. Results : Average plaque index values (API), initial and after 4, 8 and 12 months, have not indicated significant differences between two groups of subjects. Average bleeding index values - initial (i- ABI) and after 4 months (4 m- ABI) revealed no significant differences between two tested groups. However, there was significant difference in the average bleeding index values after 8 months (8 m- ABI) between the two tested groups (Mann Whitney ’ s U test P = 0.002). Significant difference (Mann Whitney ’ s U test P < 0.001) was also observed for the average bleeding index values after 12 months (12 m- ABI) between the two groups of subjects. There was no significant difference in the mean values of probing depths between two groups of subjects. Conclusions and Clinical Implications : The results of this study showed that the impact of the abutment type (individual CAD/CAM or stock) on the average bleeding on probing was significant, especially after 8 or 12 months. The level of oral hygiene showed significant correlation with the average bleeding on probing.

periodontal evaluation ; CAD-CAM ; abutment

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

243-243.

2017.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Clinical oral implants research

Heitz-Mayfield Lisa J. A.

Hong Kong: John Wiley & Sons

1600-0501

Podaci o skupu

26th Annual Scientific Meeting of the European Association for Osseointegration

poster

05.10.2017-07.10.2017

Madrid, Španjolska

Povezanost rada

Dentalna medicina

Indeksiranost