Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them (CROSBI ID 242508)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Saračević, Andrea ; Dukić, Lora ; Juričić, Gordana ; Milevoj Kopčinović, Lara ; Mirošević, Gorana ; Šimundić, Ana-Maria Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them // Clinical chemistry and laboratory medicine, 56 (2018), 2; 236-241. doi: 10.1515/cclm-2017-0279

Podaci o odgovornosti

Saračević, Andrea ; Dukić, Lora ; Juričić, Gordana ; Milevoj Kopčinović, Lara ; Mirošević, Gorana ; Šimundić, Ana-Maria

engleski

Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them

The aim of our study was to determine the difference between glucose concentration measured 30 min after venipuncture in ice- chilled heparin plasma sample and all currently available citrate buffer-containing tubes (Greiner Glucomedics, Greiner FC Mix and Sarstedt GlucoEXACT) and still widely used sodium fluoride/potassium oxalate (NaF/Kox) tubes from Greiner. Blood was collected from 20 healthy volunteers and 20 patients with diabetes into LiH, NaF/KOx, Glucomedics, FC mix and GlucoEXACT tubes. Glucose was measured within 30 min from blood sampling in duplicate on the Architect c8000 analyzer. Mean biases between all tube types were calculated and compared to the recommended criteria (1.95%). Additionally, glucose concentrations measured in all five tube types were compared using the Friedman test. In the entire studied population, glucose concentrations measured in Glucomedics, FC mix and GlucoEXACT were higher (7.3%, 3.2% and 2.0%, respectively) than in the ice-chilled LiH tubes. When all glycolysis inhibitor-containing tubes were compared, Glucomedics tubes significantly differed from GlucoEXACT and FC mix tubes (biases −4.9% and 4.0%, respectively). In addition, there was a significant difference between the NaF/KOx tube and Glucomedics, as well as FC mix tubes (biases 7.1% and 3.0%, respectively). Glucose concentrations measured in recommended ice-chilled lithium heparin- and citrate buffer-containing tubes are not comparable. Significant biases exist between various glycolysis inhibitor-containing tubes ; therefore, they cannot be used interchangeably.

citrate buffer ; diabetes mellitus ; glycolysis ; glycolysis inhibitor ; preanalytical phase

Rad/časopis indeksiran je i u bazama: Pathway Studio ; Primo Central (ExLibris) ; ProQuest ; Rad/časopis je indeksiran i u Bazama: Pathway Studio ; Primo Central ; ProQuestPublons ; PubsHub ; QOAM ; ReadCube ; Reaxys ; SCImago (SJR) ; Sherpa/RoMEO ; Summon ; TDNet ; TEMA ; Text Mining ; ulrichsweb ; WanFang Data ; WorldCat

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

56 (2)

2018.

236-241

objavljeno

1434-6621

1437-4331

10.1515/cclm-2017-0279