Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Blood Glucose Determination: Effect of Tube Additive (CROSBI ID 242507)

Prilog u časopisu | pregledni rad (znanstveni) | međunarodna recenzija

Lippi, Giuseppe ; Nybo, Mads ; Cadamuro, Janne ; Guimaraes, Joao T. ; van Dongen-Lases, Edmee ; Šimundić, Ana-Maria Blood Glucose Determination: Effect of Tube Additive // Advances in clinical chemistry, 84 (2018), 101-123. doi: 10.1016/bs.acc.2017.12.003

Podaci o odgovornosti

Lippi, Giuseppe ; Nybo, Mads ; Cadamuro, Janne ; Guimaraes, Joao T. ; van Dongen-Lases, Edmee ; Šimundić, Ana-Maria

engleski

Blood Glucose Determination: Effect of Tube Additive

The measurement of fasting plasma glucose may be biased by a time-dependent decrease of glucose in blood tubes, mainly attributable to blood cell metabolism when glycolysis is not rapidly inhibited or blood cells cannot be rapidly separated from plasma. Although glycolysis inhibitors such as sodium fluoride (NaF) in combination with potassium oxalate (KOx) are currently used for overcoming this drawback, their efficacy for stabilizing blood glucose is seemingly limited, and probably lower than that of newer additives such as the citrate buffer. Therefore, we performed a critical analysis of the current scientific literature aimed to generate evidence-based information about the advantages of using citrate buffer in blood tubes compared to the more conventional NaF additive. The results of our systematic overview of the literature show that citrate blood tubes represent a considerable step forward in achieving more accurate and reliable plasma glucose measurements, thereby limiting the risk of underdiagnosing diabetes due to spurious decrease of glucose concentration in uncentrifuged blood specimens, ensuring higher stability of glucose levels over time, while simultaneously producing less hemolysis compared to NaF blood tubes. Therefore, we suggest that the use of this new mixture should be encouraged for achieving a higher degree of accuracy and standardization of plasma glucose measurements.

tube additives ; glucose

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

84

2018.

101-123

objavljeno

0065-2423

10.1016/bs.acc.2017.12.003

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost