Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Practical Approach for Parameter Determinations of Interior Permanent Magnet Generator (CROSBI ID 650222)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Jukić, Filip ; Sumina, Damir ; Pravica, Luka ; Kuzle, Igor Practical Approach for Parameter Determinations of Interior Permanent Magnet Generator // IEEE EUROCON 2017 / Karadzinov, Ljupco ; Cvetkovski, Goga ; Latkoski, Pero (ur.). Skopje: Institute of Electrical and Electronics Engineers (IEEE), 2017. str. 712-717 doi: 10.1109/EUROCON.2017.8011204

Podaci o odgovornosti

Jukić, Filip ; Sumina, Damir ; Pravica, Luka ; Kuzle, Igor

engleski

Practical Approach for Parameter Determinations of Interior Permanent Magnet Generator

Recently, there has been a lot of researches on various methods for a sensorless control of permanent magnet generators (PMG) in wind turbines. The sensorless control of the PMG considers estimations of a rotor angle and speed which are based on the PMG parameters estimation. The parameters that have been estimated are stator resistance, rotor flux, d- axis and q-axis inductance. For more precise rotor angle and speed estimation, it is essential to determinate values of the PMG parameters in every operating point as accurately as possible. A change of the operating point (different rotor speed, shaft torque etc.) causes the change of the PMG parameters due to stator currents and temperature variation. Accordingly, the PMG parameters could be measured during a PMG commissioning. In this work, the stator resistance is measured while taking into considering a dead time compensation and voltage drop on a power switching devices. A determination of the d-axis and q-axis inductances is based on PMG voltage equations in a dq synchronous reference frame. Thus, the measurements of the rotor speed, stator currents and voltages are required. The experimental measurements are carried out on a 375 kW interior permanent magnet generator. Finally, the measured values could be saved on a digital signal processor (DSP) as look-up tables and used for the sensorless control of the PMG.

permanent magnet generator, parameter determination, stator resistance, rotor flux linkage, d-axis inductance, q-axis inductance

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

712-717.

2017.

objavljeno

10.1109/EUROCON.2017.8011204

Podaci o matičnoj publikaciji

IEEE EUROCON 2017

Karadzinov, Ljupco ; Cvetkovski, Goga ; Latkoski, Pero

Skopje: Institute of Electrical and Electronics Engineers (IEEE)

978-1-5090-3842-8

Podaci o skupu

17th IEEE International Conference on Smart Technologies (IEEE EUROCON 2017)

predavanje

06.07.2017-08.07.2017

Ohrid, Sjeverna Makedonija

Povezanost rada

Elektrotehnika

Poveznice