Measurement of the mass difference between top quark and antiquark in pp collisions at sqrt(s) = 8 TeV (CROSBI ID 239244)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Khachatryan, Vardan ; ... ; Pleština, R. ; ... ; Godinović, Nikola ; Lelas, Damir ; Puljak, Ivica ; ... ; Antunović, Željko ; Kovač, Marko ; Brigljević, Vuko ; Kadija, Krešo ; Luetić, Jelena ; Mićanović, Saša ; Sudić, Lucija ; ... ; Morović, Srećko ; ... ; Ferenček, Dinko ; ... ; Đurić, Senka ; ... ; Woods, Nate
CMS Collaboration
engleski
Measurement of the mass difference between top quark and antiquark in pp collisions at sqrt(s) = 8 TeV
The invariance of the standard model (SM) under the CPT transformation predicts equality of particle and antiparticle masses. This prediction is tested by measuring the mass difference between the top quark and antiquark (Delta m[t] = m[t] - m[t-bar]) that are produced in pp collisions at a center-of-mass energy of 8 TeV, using events with a muon or an electron and at least four jets in the final state. The analysis is based on data corresponding to an integrated luminosity of 19.6 inverse femtobarns collected by the CMS experiment at the LHC, and yields a value of Delta m[t] = -0.15 +/- 0.19 (stat) +/- 0.09 (syst) GeV, which is consistent with the SM expectation. This result is significantly more precise than previously reported measurements.
high energy physics ; experimental particle physics ; LHC ; CMS ; standard model