Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Prenatal ultrasonographic detection of gastrointestinal obstruction: results from 18 European congenital anomaly registries. (CROSBI ID 95566)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Haeusler, Martin ; Berghold, Andrea ; Stoll, Claude ; Barišić, Ingeborg ; Clementi, Maurizio ; EUROSCAN Study Group. Prenatal ultrasonographic detection of gastrointestinal obstruction: results from 18 European congenital anomaly registries. // Prenatal diagnosis, 22 (2002), 7; 616-623-x

Podaci o odgovornosti

Haeusler, Martin ; Berghold, Andrea ; Stoll, Claude ; Barišić, Ingeborg ; Clementi, Maurizio ; EUROSCAN Study Group.

engleski

Prenatal ultrasonographic detection of gastrointestinal obstruction: results from 18 European congenital anomaly registries.

OBJECTIVES: We evaluated the prenatal detection of gastrointestinal obstruction (GIO, including atresia, stenosis, absence or fistula) by routine ultrasonographic examination in an unselected population all over Europe. METHODS: Data from 18 congenital malformation registries in 11 European countries were analysed. These multisource registries used the same methodology. All fetuses/neonates with GIO confirmed within 1 week after birth who had prenatal sonography and were born during the study period (1 July 1996 to 31 December 1998) were included. RESULTS: There were 670 793 births in the area covered and 349 fetuses/neonates had GIO. The prenatal detection rate of GIO was 34% of these 40% were detected < or = 24 weeks of gestation (WG). A total of 31% (60/192) of the isolated GIO were detected prenatally, as were 38% (59/157) of the associated GIO (p=0.26). The detection rate was 25% for esophageal obstruction (31/122), 52% for duodenal obstruction (33/64), 40% for small intestine obstruction (27/68) and 29% for large intestine obstruction (28/95) (p=0.002). The detection rate was higher in countries with a policy of routine obstetric ultrasound. Fifteen percent of pregnancies were terminated (51/349). Eleven of these had chromosomal anomalies, 31 multiple malformations, eight non-chromosomal recognized syndromes, and one isolated GIO. The participating registries reflect the various national policies for termination of pregnancy (TOP), but TOPs after 24 WG (11/51) do not appear to be performed more frequently in countries with a liberal TOP policy. CONCLUSION: This European study shows that the detection rate of GIO depends on the screening policy and on the sonographic detectability of GIO subgroups.

birth defects; intestinal atresia; gastrointestina obstruction; fetal ultrasound screening; registry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

22 (7)

2002.

616-623-x

objavljeno

0197-3851

Povezanost rada

Javno zdravstvo i zdravstvena zaštita

Indeksiranost