Application of ASTEC, MELCOR, and MAAP Computer Codes for Thermal Hydraulic Analysis of a PWR Containment Equipped with the PCFV and PAR Systems (CROSBI ID 239048)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šadek, Siniša ; Grgić, Davor ; Šimić, Zdenko Application of ASTEC, MELCOR, and MAAP Computer Codes for Thermal Hydraulic Analysis of a PWR Containment Equipped with the PCFV and PAR Systems // Science and technology of nuclear installations, (2017), 8431934-1-8431934-16. doi: 10.1155/2017/8431934

Podaci o odgovornosti

Šadek, Siniša ; Grgić, Davor ; Šimić, Zdenko

engleski

Application of ASTEC, MELCOR, and MAAP Computer Codes for Thermal Hydraulic Analysis of a PWR Containment Equipped with the PCFV and PAR Systems

The integrity of the containment will be challenged during a severe accident due to pressurization caused by the accumulation of steam and other gases and possible ignition of hydrogen and carbon monoxide. Installation of a passive filtered venting system and passive autocatalytic recombiners allows control of the pressure, radioactive releases, and concentration of flammable gases. Thermal hydraulic analysis of the containment equipped with dedicated passive safety systems after a hypothetical station blackout event is performed for a two-loop pressurized water reactor NPP with three integral severe accident codes: ASTEC, MELCOR, andMAAP.MELCOR and MAAP are two major US codes for severe accident analyses, and the ASTEC code is the European code, joint property of Institut de Radioprotection et de Sˆuret´e Nucl´eaire (IRSN, France) and Gesellschaft f¨ur Anlagen und Reaktorsicherheit (GRS, Germany). Codes’ overall characteristics, physics models, and the analysis results are compared herein. Despite considerable differences between the codes’ modelling features, the general trends of the NPP behaviour are found to be similar, although discrepancies related to simulation of the processes in the containment cavity are also observed and discussed in the paper.

ASTEC, MELCOR, MAAP, Containment, PCFV, PAR

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

nije evidentirano

2017.

8431934-1-8431934-16

objavljeno

1687-6075

10.1155/2017/8431934

Povezanost rada

nije evidentirano

Poveznice
Indeksiranost