Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Thermodynamical analysis of high-pressure feed water heater in steam propulsion system during exploitation (CROSBI ID 238993)

Prilog u časopisu | prethodno priopćenje | domaća recenzija

Mrzljak, Vedran ; Poljak, Igor ; Medica-Viola, Vedran Thermodynamical analysis of high-pressure feed water heater in steam propulsion system during exploitation // Brodogradnja, 68 (2017), 2; 45-61. doi: 10.21278/brod68204

Podaci o odgovornosti

Mrzljak, Vedran ; Poljak, Igor ; Medica-Viola, Vedran

engleski

Thermodynamical analysis of high-pressure feed water heater in steam propulsion system during exploitation

Nowadays diesel engines prevail as ship propulsion. However, steam propulsion is still primary drive for LNG carriers. In the presented paper high-pressure feed water heater was analyzed, as one of the essential components in LNG carrier steam propulsion system. Measurements of all operating parameters (fluid streams) at the analyzed heat exchanger inlets and outlets were performed. Change of the operating parameters was measured at different steam system loads, not at full load as usual. Through these measurements was enabled the insight into the behaviour of the heat exchanger operating parameters during the whole exploitation. The numerical analysis was performed, based on the measured data. The changes in energy and exergy efficiency of the heat exchanger were analyzed. Energetic and exergetic power inputs and outputs were also calculated, which enabled an insight into the change of energetic and exergetic power losses of the heat exchanger at different steam system loads. Change in energetic and exergetic power losses and operating parameters, which have the strongest influence on the high-pressure feed water heater losses, were described. Analyzed heat exchanger was compared with similar heat exchangers in the base loaded conventional steam power plants. From the conducted analysis, it is concluded that the adjustment and control modes of these high- pressure heat exchangers are equal, regardless of whether they were mounted in the base loaded conventional steam power plants or marine steam systems, while their operating parameters and behaviour patterns differ greatly.

High-pressure feed water heater ; Energy efficiency ; Energetic power loss ; Exergy efficiency ; Exergetic power loss

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

68 (2)

2017.

45-61

objavljeno

0007-215X

1845-5859

10.21278/brod68204

Povezanost rada

Strojarstvo

Poveznice
Indeksiranost