The electrode setup for vibratory evoked potentials (CROSBI ID 647252)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Krbot Skorić, Magdalena ; Cifrek, Mario ; Krois, Igor ; Jerbić, Ana Branka ; Išgum, Velimir The electrode setup for vibratory evoked potentials // Proceedings of the International Conference on Medical and Biological Engineering 2017 / Badnjević, Almir (ur.). Springer, 2017. str. 557-562

Podaci o odgovornosti

Krbot Skorić, Magdalena ; Cifrek, Mario ; Krois, Igor ; Jerbić, Ana Branka ; Išgum, Velimir

engleski

The electrode setup for vibratory evoked potentials

The difficulties related to the sense of vibration could be characteristics of the specific neurological disorders, so there is a need for measurable and quantifiable information about its functionality. Currently used methods for testin g the sense of vibration do not provide appropriate information, and new method of vibratory stimulation was introduced in the area of the neurophysiological research. Method provides repeatable and quantifiable information about the evoked cortical activi ty, but there was a need for information about the functional integrity of the whole vibratory sensory pathways. The result of this research was the electrode setup that provides information from the Erb’s point through the levels of the cervical spine to the contralateral sensory area at the cortex. Also, the setup consists only of four electrodes for each side of the stimulation (six electrodes all together, because electrodes positioned on the cervical spinal cord are common for both sides of the body), which reduce time necessary for preparation and allows better use for clinical purposes

the sense of vibration, vibratory evoked potentials, vibratory stimulation, number of electrodes

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

557-562.

2017.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the International Conference on Medical and Biological Engineering 2017

Badnjević, Almir

Springer

978-981-10-4166-2

Podaci o skupu

International Conference on Medical and Biological Engineering in Bosnia and Herzegovina (CMBEBIH 2017)

predavanje

16.03.2017-18.03.2017

Sarajevo, Bosna i Hercegovina

Povezanost rada

nije evidentirano

Poveznice