An improved apparatus for vapor–liquid equilibria measurement in systems containing polymer at higher temperatures (CROSBI ID 647152)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Pavlíček, Jan ; Bogdanić, Grozdana ; Wichterle, Ivan An improved apparatus for vapor–liquid equilibria measurement in systems containing polymer at higher temperatures // 29th European Symposium on Applied Thermodynamics, Book of Abstracts / Catinca Secuianu (ur.). Bukurešt, 2017. str. 236-236

Podaci o odgovornosti

Pavlíček, Jan ; Bogdanić, Grozdana ; Wichterle, Ivan

engleski

An improved apparatus for vapor–liquid equilibria measurement in systems containing polymer at higher temperatures

The apparatus for total pressure measurement in polymer + solvent systems has been designed recently [1]. In the presented work, the range of functioning of this apparatus was extended to allow investigations at higher temperatures. A direct capacitance pressure sensor (Baratron) was replaced by a pressure transducer, which may be heated up to 200 oC. This is the main feature of the apparatus preventing from condensation of solvent vapors in the pressure cell. Other parts of the whole equipment can be maintained at temperature higher than the system with use of heating tapes. In addition, the solutions with higher concentrations of polymer can be studied in contrast to the ebulliometric method, which is limited because of problems with physical boiling of viscous mixtures. The apparatus was tested using known data. Moreover, the existing data on the poly(ethylene glycol) + water system were supplemented by new experiments covering both the wider range of isotherms and higher molecular masses of polymer. References [1] J. Pavlíček, G. Bogdanić, I. Wichterle, Chem. Eng. Technol., 40 (2017) 991–996.

total pressure measurement ; polymer+solvent system ; new apparatus

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

236-236.

2017.

objavljeno

Podaci o matičnoj publikaciji

Catinca Secuianu

Bukurešt:

Podaci o skupu

29th European Symposium on Applied Thermodynamics

poster

18.05.2017-21.05.2017

Bukurešt, Rumunjska

Povezanost rada

Temeljne tehničke znanosti