Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The Influence of Galilean and Kepler Loupe Systems Under Simulated Clinical Conditions (CROSBI ID 646931)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Urlić, Iris ; Negovetić Vranić, Dubravka ; Carek, Andreja ; Verzak, Željko ; Dumančić, Jelena ; Rajić, Valentina ; Vucelić, Vesna The Influence of Galilean and Kepler Loupe Systems Under Simulated Clinical Conditions // Journal of dental research. 2017. str. xx-xx

Podaci o odgovornosti

Urlić, Iris ; Negovetić Vranić, Dubravka ; Carek, Andreja ; Verzak, Željko ; Dumančić, Jelena ; Rajić, Valentina ; Vucelić, Vesna

engleski

The Influence of Galilean and Kepler Loupe Systems Under Simulated Clinical Conditions

Objectives: The purpose of the study was to compare near visual acuity of dentists with use of the Galilean telescope system (VGA2) with magnification of x 2.5 , distance of 350 mm with use of the Kepler telescope system (VK3, 3) with magnification of x 3.3 , distance of 450 mm in simulated clinical conditions. Methods: The study included 50 dentists (visual acuity 1.0 without correction). Miniaturized Snellen visual test was placed in the molar cavity of dental phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1) with Galilean loupes, magnification of x2.5, focal length 350mm 2) with Kepler telescope system (VK3, 3), magnification of x 3.3 , distance of 450 mm in simulated clinical conditions. Results: The distribution of near visual acuity recorded using VGA2, 5 and VK3, 3 systems were compared by the Wilcoxon Signed Rank test. Results by Wilcoxon Signed Rank test indicated a statistically significant difference in the distribution of recorded visual acuity between VGA 2, 5 and VK3, 3 optical system (W = - 102 ; p <0.001). Conclusions: Using VK3, 3 system higher values of near visual acuity were recorded compared to near visual acuity with Galilean magnifying aids (VG2, 5).

visual acuity ; Galilean optical systems ; dental loupes

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

xx-xx.

2017.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Journal of dental research

0022-0345

1544-0591

Podaci o skupu

Iadr General Session

poster

22.03.2017-25.03.2017

San Francisco (CA), Sjedinjene Američke Države

Povezanost rada

Dentalna medicina