Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Relation between microclimate and air quality in the extensively reared turkey house (CROSBI ID 237382)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ostović, Mario ; Menčik, Sven ; Ravić, Ivica ; Žužul, Slavko ; Pavičić, Željko ; Matković, Kristina ; Antunović, Boris ; Horvatek Tomić, Danijela ; Ekert Kabalin, Anamaria Relation between microclimate and air quality in the extensively reared turkey house // Macedonian veterinary review, 40 (2017), 1; 83-90

Podaci o odgovornosti

Ostović, Mario ; Menčik, Sven ; Ravić, Ivica ; Žužul, Slavko ; Pavičić, Željko ; Matković, Kristina ; Antunović, Boris ; Horvatek Tomić, Danijela ; Ekert Kabalin, Anamaria

engleski

Relation between microclimate and air quality in the extensively reared turkey house

Good air quality in poultry houses is crucial for animal health and productivity. In these houses, air is generally contaminated with noxious gases and microorganisms, the concentrations of which depend on numerous factors including microclimate. In this case study, the relation between microclimate and air concentrations of noxious gases and microorganisms was investigated in extensively reared turkey house. The study was carried out at a family household in Dalmatia hinterland, Croatia, with 50.3±3.1 turkeys kept in the house during the study period. Air temperature, relative humidity, airflow rate, concentrations of ammonia, carbon dioxide, bacteria and fungi in indoor air were measured three times per month from September to December, in the morning, prior to releasing turkeys out for grazing. Air temperature ranged from 9.73 to 26.98 °C, relative humidity from 63.29% to 75.08%, and airflow rate from 0.11 to 0.17 m/s. Lowest ammonia and carbon dioxide concentrations were measured in September (2.17 ppm and 550 ppm, respectively) and highest in December (4.50 ppm and 900 ppm, respectively). Bacterial and fungal counts were lowest in December (2.51x105 CFU/m3 and 3.27x103 CFU/m3 air, respectively) and highest in September (6.85x105 CFU/m3 and 1.06x105 CFU/m3 air, respectively). Air temperature and relative humidity showed negative correlation with concentrations of noxious gases and positive correlation with air microorganisms (P<0.05 all).

turkeys ; ammonia ; carbon dioxide ; bacteria ; fungi

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

40 (1)

2017.

83-90

objavljeno

1409-7621

Povezanost rada

Veterinarska medicina

Poveznice
Indeksiranost