Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Catode ray tube recycling (CROSBI ID 645704)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Anić Vučinić, Aleksandra ; Radetić, Lucija ; Gotal Dmitrović, Lovorka Catode ray tube recycling // Uniting ideas for successful waste management / Stanisavljević, N. ; Fellner, J. ; Hassain, S. et al. (ur.). Novi Sad: Univerzitet u Novom Sadu, 2016. str. 1873-1881

Podaci o odgovornosti

Anić Vučinić, Aleksandra ; Radetić, Lucija ; Gotal Dmitrović, Lovorka

engleski

Catode ray tube recycling

The amount of Waste Electrical and Electronic Equipment (WEEE) has grown considerably in the last years due to the advancement of technology and shorter life cycle of electric and electronic equipment (EEE). Old CRT (Cathode Ray Tube) monitors are replaced with LCD (Liquid Cristal Display) and plasma monitors. Due to toxic materials such as lead, cadmium, barium, and fluorescent powders that CRT monitors contain they are classified as hazardous waste. In nowadays, there are two possible approaches to the management of waste CRTs, landfilling and recycling. Landfilling is the least waste management option for waste CRTs since they must be disposed on hazardous waste landfill. In accordance with circular economy, recycling is more favourable option but is limited because of high lead concentrations. For purpose of research presented in this paper, front and rear CRT glasses were obtained from treatment facility during 2013, 2014 and 2015. Samples were separately crushed and sieved. Experimental monitoring was carried out in mentioned period in order to determine possible leaching of lead from different fraction sizes of front and rear CRT glasses. Research has shown that lead is leached in higher concentrations from smaller fractions of rear CRT glasses, while lead was not leached from crushed front CRT glasses. Only two fractions of rear CRT glasses were classified as a hazardous waste.

Cathode ray tubes (CRTs), leaching test, lead, hazardous waste

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1873-1881.

2016.

objavljeno

Podaci o matičnoj publikaciji

Uniting ideas for successful waste management

Stanisavljević, N. ; Fellner, J. ; Hassain, S. ; Lewis, J.W.

Novi Sad: Univerzitet u Novom Sadu

978-86-7892-837-6

Podaci o skupu

World Congress ISWA 2016 "Uniting ideas for successful waste manegement"

poster

19.09.2016-21.09.2016

Novi Sad, Srbija

Povezanost rada

Kemijsko inženjerstvo, Interdisciplinarne tehničke znanosti