Peak Power Output Test on a Rowing Ergometer : A Methodological Study (CROSBI ID 235917)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Metikoš, Boris ; Mikulić, Pavle ; Šarabon, Nejc ; Marković, Goran Peak Power Output Test on a Rowing Ergometer : A Methodological Study // Journal of strength and conditioning research, 29 (2015), 10; 2919-2925. doi: 10.1519/JSC.0000000000000944

Podaci o odgovornosti

Metikoš, Boris ; Mikulić, Pavle ; Šarabon, Nejc ; Marković, Goran

engleski

Peak Power Output Test on a Rowing Ergometer : A Methodological Study

We aimed to examine the reliability and validity of the peak power output test on a rowing ergometer (Concept II Model D Inc.) and to establish the "optimal resistance" at which this peak power output was observed in 87 participants with varying levels of physical activity and rowing expertise: 15 male and 12 female physically inactive students (age: 21 ± 2 years), 16 male and 20 female physically active students (age: 23 ± 2 years), and 15 male and 9 female trained rowers (age: 19 ± 2 years). The participants performed countermovement jump (CMJ) test on a force plate, followed by 3 maximal-effort rowing trials using the lowest, medium, and the highest adjustable resistance settings (i.e., "1", "5, " and "10" on the resistance control dial on the ergometer) in randomized order. The test proved to be reliable (coefficients of variation: 2.6-6.5% ; intraclass correlation coefficients: 0.87-0.98). The correlation coefficients between CMJ peak power and rowing peak power (both in watts per kilogram) were fairly consistent across all 3 groups of participants and resistance levels, ranging between r = 0.70 and r = 0.78. Finally, the highest power output was observed at the highest resistance setting in 2 nonathletic groups (p < 0.01), whereas rowers seem to produce the highest power output at the moderate-resistance setting. We conclude that the power output test on a Concept II rowing ergometer may serve as a reliable and valid tool for assessing whole-body peak power output in untrained individuals and rowing athletes.

reliability ; validity

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

29 (10)

2015.

2919-2925

objavljeno

1064-8011

10.1519/JSC.0000000000000944

Povezanost rada

Kineziologija, Pedagogija

Poveznice
Indeksiranost