Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Flow Injection Spectrophotometric Determination of N-acetylcysteine Ethyl Ester Based on the Reduction of Copper(II)-bicinchoninic Acid Complex (CROSBI ID 642967)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Kukoč-Modun, Lea ; Tsikas, Dimitrios ; Kraljević, Tomislav ; Biočić, Maja ; Radić, Njegomir Flow Injection Spectrophotometric Determination of N-acetylcysteine Ethyl Ester Based on the Reduction of Copper(II)-bicinchoninic Acid Complex // Glasnik hemičara i tehnologa Bosne i Hercegovine = Bulletin of the Chemists and Technologists of Bosnia and Herzegovina / Korać, Fehim (ur.). 2016. str. 53-53

Podaci o odgovornosti

Kukoč-Modun, Lea ; Tsikas, Dimitrios ; Kraljević, Tomislav ; Biočić, Maja ; Radić, Njegomir

engleski

Flow Injection Spectrophotometric Determination of N-acetylcysteine Ethyl Ester Based on the Reduction of Copper(II)-bicinchoninic Acid Complex

A flow injection method of analysis was developed for the determination of a lipophilic cell-permeable cysteine derivative N-Acetylcysteine ethyl ester (NACET). NACET compared to its congener N-acetylcysteine poseses enhanced pharmacokinetic features. Once administered NACET quickly enters the cells where it is transformed to NAC and cysteine. The proposed method is based on a reduction reaction of an apple green Cu(BCA)22+ complex to a purple Cu(BCA)2+-complex by NACET in a phosphate buffer solution. The absorbance of the generated Cu(BCA)2+ complex is measured at 562 nm. Recorded peak height was used as a quantitative variable in the flow injection procedure. The absorbance of the formed Cu(BCA)2+, was recorded as a function of time with a recording frequency of 5 s–1. The linearity of the proposed flow injection method was obtained over the range 2.0×10–6 mol L-1 – 1.0×10–4 mol L–1 NACET, where the limit of detection was 6.6×10–7 mol L-1. Relative standard deviation obtained by measuring ten replicates of 4×10–5 mol L–1 NACET was found to be 0.7 %. Analytical frequency was 72 analysis per hour.

N-Acetylcysteine ethyl ester; Bicinchoninic acid; Flow injection.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

53-53.

2016.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Glasnik hemičara i tehnologa Bosne i Hercegovine = Bulletin of the Chemists and Technologists of Bosnia and Herzegovina

Korać, Fehim

Sarajevo: Prirodno-matematički fakultet Sarajevo

0367-4444

Podaci o skupu

2nd International Congress of Chemists and Chemical Engineers of Bosnia and Herzegovina.

poster

21.10.2016-23.10.2016

Sarajevo, Bosna i Hercegovina

Povezanost rada

Kemija