Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Influence of pH value on reduction of graphene oxide by olive mill wastewater (CROSBI ID 641381)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | domaća recenzija

Vrdoljak, Matea ; Radić, Gabrijela ; Sačer, Denis ; Kraljić Roković, Marijana Influence of pH value on reduction of graphene oxide by olive mill wastewater // Fourth Conference of Young Chemists of Serbia, Book of abstracts / Todorović, Tamara ; Opsenica, Igor ; Dekanski, Aleksandar (ur.). Beograd: Serbian Chemical Society, 2016. str. 87-87

Podaci o odgovornosti

Vrdoljak, Matea ; Radić, Gabrijela ; Sačer, Denis ; Kraljić Roković, Marijana

engleski

Influence of pH value on reduction of graphene oxide by olive mill wastewater

The main goal of this research was the preparation of graphene by means of chemical reduction with phenolic compounds present in olive vegetation water at various pH values. The reduction of GO has been carried out at pH 7 and 10 and temperature of 80°C using olive leaf extract (OLE)solution and olive mill wastewater (OMW). The duration of the experiments was five hours, resulting in rGO(OLE, pH 7), rGO(OLE, pH 10) and rGO(OMW, pH 10) products. The course of the reduction was monitored using UV/Vis. The obtained products were characterized using cyclic voltametry, EIS, TGA, IR spectroscopy and four point probe method. Three different samples of rGO have been examined by cyclic voltametry during which a glassy carbon (GC) electrode was used as a current collector. rGO(OLE, pH 10) sample has shown the best capacitive properties. Some residual polyphenolic compounds have been noticed in rGO(OMW, pH 10) sample, as a result, anodic and cathodic current peaks were formed in the cyclic voltammogram. The highest specific capacitance, 25.11 F g-1, has been registered for rGO(OMW, pH 10) sample. By comparing capacitance of rGO(OLE, pH 10) and rGO(OLE, pH 7) samples it has been found that materials obtained by reduction at a higher pH value have better specific capacitance values.

graphene oxide ; reduced graphene oxide ; olive mill wastewater

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

87-87.

2016.

objavljeno

Podaci o matičnoj publikaciji

Fourth Conference of Young Chemists of Serbia, Book of abstracts

Todorović, Tamara ; Opsenica, Igor ; Dekanski, Aleksandar

Beograd: Serbian Chemical Society

978-86-7132-064-1

Podaci o skupu

FOURTH CONFERENCE OF YOUNG CHEMISTS OF SERBIA

poster

05.11.2016-05.11.2016

Beograd, Srbija

Povezanost rada

Kemija, Kemijsko inženjerstvo, Temeljne tehničke znanosti

Poveznice