Suppression of shaft vibration at HPP Dubrava unit 1 based on detailled rotor diagnostics (CROSBI ID 484007)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Dvekar, Đuro ; Bajić, Branko ; Bacinger, Ivan ; Sabolek, Josip ; Demirović, Muharem
engleski
Suppression of shaft vibration at HPP Dubrava unit 1 based on detailled rotor diagnostics
The way used to suppress vibration on HPP Dubrava bulb unit 1 caused by loosening of the keyed spider-shaft joint is described. The spider was precisely positioned on the shaft. This step was based on the extensive diagnostic tests and a detailed analysis of rotor kinematics and dynamics. The spider is fixed by the elements that are resistive to the existing types of fretting.
shaft; spider; rotor; vibration; diagnostics
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
287-290-x.
2001.
objavljeno
Podaci o matičnoj publikaciji
Hydro 2001: Opprortunities and Challenges
Sutton: The International Journal on Hydropowers & Dams
Podaci o skupu
Hydro 2001: Opprortunities and Challenges
predavanje
27.09.2001-29.09.2001
Riva del Garda, Italija