Station Blackout Severe Accident Calculation Using MELCOR 1.8.3 Computer Code (CROSBI ID 465264)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Bajs, Tomislav ; Matanić, Renata ; Jurković, Ines-Ana Station Blackout Severe Accident Calculation Using MELCOR 1.8.3 Computer Code // Nuclear Option in Countries with Small and Medium Electricity Grid / Knapp, Vladimir ; Čavlina, Nikola (ur.). Hrvatsko nuklearno društvo, 1996. str. 440-447-x

Podaci o odgovornosti

Bajs, Tomislav ; Matanić, Renata ; Jurković, Ines-Ana

engleski

Station Blackout Severe Accident Calculation Using MELCOR 1.8.3 Computer Code

The overall objective of reactor safety is to protect the public and the environment against dangerous releases of radioactive materials from nuclear power plants. A nuclear power plant is designed to cope with a set of events including normal conditions, anticipated operational occurrences, external events and accidents. Station blackouts a severe accident that might produce core melt and major releases of fission products from the reactor core. This paper shows the results of station blackout(SBO) analysis of NPP Krško model, by using MELCOR, a computer code that models the progression of severe accidents in LWR nuclear power plants. MELCOR was developed by Sandia National Laboratories for US Nuclear Regulatory Commission as a successor to the Source term code package. Calculations were realised at Faculty of Electrical Engineering and Computer Science, Department of Power Systems. The main goal of this analysis was to investigate the possibilities and the operation of MELCOR and to develop a model of NPP Krško for further calculations. Therefore, at this stage, modelling is rather simplified and requires more detailed study of code packages and code itself. The results of SBO analysis show that, depending on initial conditions, SBO accidents a serious threat to safety barriers integrity and in this case leads to the damage of containment building, but they also show that MELCOR enables detailed calculations of long-term accident progression.

reactor safety; station blackouts; severe accidents

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

440-447-x.

1996.

objavljeno

Podaci o matičnoj publikaciji

Nuclear Option in Countries with Small and Medium Electricity Grid

Knapp, Vladimir ; Čavlina, Nikola

Hrvatsko nuklearno društvo

Podaci o skupu

International Conference: Nuclear Option in Countries with Small and Medium Electricity Grid

poster

07.10.1996-09.10.1996

Opatija, Hrvatska

Povezanost rada

Elektrotehnika